基于某城区供热管网现状,指出城北至城南供热管网互联互通的意义,详细分析了互联互通管网的路由、事故工况下供热量保证率以及互联互通管网的管径,同时对联通管网水力工况进行了探讨,为正确的进行供热管网设计提供了理论指导。
Based on the present situation of district heating network in Harbin,this paper points out the significance of the interconnection of the heating network between the northern part and the southern part of district,analyzes in detail the interconnection network routing,the heat supply rate under accident conditions and the pipe diameter of the interconnected pipe network,at the same time discusses the regional pipe network hydraulic operating conditions,and provides theoretical guidance for the proper design of heating network.
作者
王方
王全福
赵云鹏
倪珅
WANG Fang;WANG Quan-fu;ZHAO Yun-peng;NI Shen(Heilongjiang Construction Investment Urban Design Co.,Ltd.,Harbin 150025,China;Heilongjiang College of Construction,Harbin 150025,China)
出处
《应用能源技术》
2021年第10期26-29,共4页
Applied Energy Technology
关键词
供热管网
互联互通
供热量保证率
路由
管径
水力工况
heating network
interconnection
heat supply rate
routing
circulating pump
hydraulic operating conditions