摘要
本文依据气承式充气膜结构的特点,以淄博日日顺创新产业园建设项目二期5#物流仓库为例,简要介绍充气膜建筑的火灾特点及该结构的防火设计方案。在火灾危险性评价和膜材燃烧实验的基础上,优化灭火与救援方式设计,强化此特殊类型建筑的防火性能。
Based on the features of air-supported membrane structure,this paper introduces the fire characteristics of the membrane building and the special fire prevention design scheme by taking No.5 logistics warehouse of Zibo Ririshun Innovation Industrial Park as an example.Based on risk analysis and membrane burning experiment,the fire prevention feature of the storage is strengthened by optimizing the measures of fire fighting and evacuation.
作者
荣超
刘崇
姚斌
Rong Chao;Liu Chong;Yao Bin(Qingdao Haier Industrial Development Co.,Ltd.,Qingdao Shandong 266035,China;College of Architecture and Urban Planning,Qingdao University of Technology,Qingdao Shandong 266033,China;State Key Laboratory of Fire Science University of Science and Technology of China,Hefei Anhui 230026,China)
出处
《城市建筑》
2021年第27期123-125,共3页
Urbanism and Architecture
关键词
充气膜结构
仓库
火灾特点
事故树
消防设计
建筑设计
air-supported membrane structure
storage
fire feature
accident tree
fire prevention design