摘要
为提高磁体系统安装精度,在HL-2M集成大厅建立63个基准点构成测量基准网,并利用激光跟踪仪等高精度测量设备建立每个磁体的局部坐标系,测量特征点的局部坐标;基于测量基准网和公共测量点,采用最佳拟合得到坐标转换矩阵,以此得到特征点在测量基准网的位置,指导磁体安装。完成安装后的中心柱同支撑基础的同轴度为∅2.03mm;PF1~PF4线圈安装标高偏差为±0.5mm,与中心柱的同轴度为∅2.60mm;PF5/6/7/8线圈与中心柱的同轴度偏差小于∅3.00mm,标高偏差在[-1mm,1mm]区间内。基于以上方法所得到的线圈安装精度都满足设计需求。
To improve the magnet system installation accuracy,63 reference points were installed in the HL-2M hall to form a measurement reference network.The local coordinates of the characteristic points on every coil were measured with the established local coordinate system and the high-precision measuring equipment such as the laser tracker.And then the coordinates of these points were converted to the installation coordinate system through the reference network and the best fit,which could be used for the positioning of the coils.When the integration of these coils was completed,the coaxality between the center column of toroidal field(TF)coils and the supporting foundation was∅2.03mm.The elevation deviation of the PF1~4 coils was±0.5mm,and the coaxality with the center column was∅2.60mm.The coaxality between the PF5~8 coils and the center column was below∅3.00mm,and the elevation deviation of these coils was within the interval of[-1mm,1mm].So,the installation accuracy of these coils meet the installation requirements.
作者
张龙
刘健
赖春林
刘宽程
查方正
蔡立君
卢勇
黄文玉
HL-2M研制团队
ZHANG Long;LIU Jian;LAI Chun-lin;LIU Kuan-cheng;ZA Fang-zheng;CAI Li-jun;LU Yong;HUANG Wen-yu;HL-2M Development Team(Southwestern Institute of Physics,Chengdu 610041)
出处
《核聚变与等离子体物理》
CAS
CSCD
北大核心
2021年第S01期321-326,共6页
Nuclear Fusion and Plasma Physics
关键词
HL-2M装置
磁体系统
安装集成
基准网
定位装配
HL-2M tokamak
Magnet system
Installation integration
Reference net