期刊文献+

直接注入管线失水事故非能动安全系统运行特性研究

Experimental Study on DVI Line Break LOCA with Passive Safety System
下载PDF
导出
摘要 小型模块式反应堆ACP100采用了非能动安全和模块化设计技术,可用于地区集中供暖、海水淡化和核动力商船等多个方面。其中,非能动安全设计主要包括非能动应急堆芯冷却系统、非能动余热排出系统等非能动安全系统和自动卸压等专设措施。针对ACP100非能动安全设计技术特点,在中国核动力研究设计院非能动安全系统综合性能缩比试验装置上开展了大量失水事故系统特性试验研究,根据试验数据分析,获得了非能动安全系统在直接注入管线发生破口后系统的综合响应特性,掌握了系统间的相互影响规律,并初步评估其对堆芯的冷却效果。 Small modular reactor ACP100 adopts passive safety system and modular design technology and can be applied in district heating,seawater desalination and nuclear power ship,etc.The passive safety design mainly includes automatic rapid depressurization system,passive emergency core cooling system and residual heat removal system.For validation and verification of design features of the ACP100,a series of LOCA experiments were finished on a scaled integral test facility in Nuclear Power Institute of China.The system comprehensive response characteristics under DVI line break condition were obtained based on the experimental data.The influential patterns between systems were obtained and the core cooling effect was preliminarily evaluated.
作者 黄志刚 张妍 鲁晓东 彭传新 昝元锋 卓文彬 闫晓 HUANG Zhigang;ZHANG Yan;LU Xiaodong;PENG Chuanxin;ZAN Yuanfeng;ZHUO Wenbin;YAN Xiao(CNNC Key Laboratory on Nuclear Reactor Thermal Hydraulics Technology,Nuclear Power Institute of China,Chengdu 610213,China)
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2021年第11期2021-2027,共7页 Atomic Energy Science and Technology
关键词 ACP100非能动安全系统 直接注入管线 失水事故 ACP100 passive safety system DVI line LOCA
  • 相关文献

参考文献6

二级参考文献30

  • 1张大林,秋穗正,苟军利,贾斗南.新型氮气稳压器系统稳态和瞬态特性研究[J].核动力工程,2006,27(z1):38-42. 被引量:5
  • 2张雪松,刘吉堂,刘文林,刘志勇.核供热堆小破口事故实验研究[J].沈阳工程学院学报(自然科学版),2006,2(2):114-116. 被引量:1
  • 3林诚格,郁祖盛,欧阳予.能动安全先进核电厂APlOOO[M].北京:原子能出版社,2008:155-157. 被引量:1
  • 4REDFIELD J A. Pressurizer performance during loss of load tests at shipping port: Analysis and test[J].NuclApli, 1986, 81(4): 173- 186. 被引量:1
  • 5BARON R C. Digital simulation of nuclear pressuri- zer[J]. Nucl Soc Eng, 1973, 52(3):283-291. 被引量:1
  • 6KURIDAN R M, BEYNON T D. A linearized non steady state model for the pressurizer of the safe integral reactor concept[J].Progress in Nu clear Energy, 1998, 33(4): 421-438. 被引量:1
  • 7JOSE N, REYES J. AP600 and AP1000 passive saety system design and testing in APEX[R]. Vienna: IAEA, 2005. 被引量:1
  • 8McADAMS W H. Heat transfer[M]. America.. Harper Row, 1983: 369-380. 被引量:1
  • 9YOUSEF W W, TARASUK J D, McKEEN W J. Experimental study of natural heat transfer [J]. Journal of Heat Transfer, 1982, 104(4):493-500. 被引量:1
  • 10齐欣,杨金宝,许晋寿.传热学基础手册[M].北京:科学出版社,1992:430-431. 被引量:1