摘要
描述了某电厂循环水过滤系统液位计的种类和故障现象,并结合现场情况对故障设备进行了分析和处理。这些方法能够快速有效地诊断和排除电厂后续同类型设备故障,有利于技术人员快速掌握该类故障的维修技能。
The types and fault phenomena of liquid level gauge in circulating water filtration system of a power plant are described,and the fault equipment is analyzed and treated in combination with the field situation.These methods can quickly and effectively diagnose and eliminate the subsequent faults of the same type of equipment in the power plant,which is conducive to technicians to quickly master the maintenance skills of such faults.
作者
杨默
石林
YANG Mo;SHI Lin(Hainan Nuclear Power Co.,Ltd.,Changjiang 572733,China)
出处
《电工技术》
2021年第18期66-66,69,共2页
Electric Engineering
关键词
液位计
腐蚀防护
鼓网
content gauge
corrosion prevention
drum net