摘要
从事故描述、事故原因和解决对策三个方面对三起110 kV电缆故障案例进行阐述,剖析了暴力施工和设施偷盗对电缆本体和中间接头的影响,并针对三起事故案例给出精益化管理模式和智能巡检技术的相关建议,为同类电缆事故分析和处理提供借鉴。
The paper concerns three fault cases of 110 kV cables in terms of three aspects including the faults and their causes as well as the countermeasures,and thereby analyzes the impacts of rough construction and facility theft on the cables and intermediate joints.In view of the above three accident cases,it puts forward relevant suggestions on the lean management mode and intelligent inspection technologies,which offers references for analysis and treatment of similar cable accidents.
作者
李演达
郑勇
杨浩
徐琮
陆家康
吴仁宜
LI Yanda;ZHENG Yong;YANG Hao;XU Cong;LU Jiakang;WU Renyi(Suzhou Power Supply Company,Suzhou 215004;Suzhou Xinwucherg Group Co.,Ltd.,Suzhou 215100)
出处
《电力安全技术》
2021年第9期17-20,共4页
Electric Safety Technology
关键词
电缆故障
暴力施工
设施偷盗
精益化管理
智能巡检
cable fault
rough construction
facility theft
lean management
intelligent inspection