期刊文献+

温和地区绿色建筑评价一项重要指标的达标方式分析 被引量:1

Analysis of Reaching the Standard of an Important Index of Green Building Evaluation in Mild Areas
下载PDF
导出
摘要 温和地区的空调冷负荷形成受太阳辐射影响较大,在不刻意提升围护结构热工性能或提升围护结构热工性能成本较高的情况下,通过选取外窗包括透光幕墙的构造特性和材料特性,降低空调负荷最终达到绿色建筑三星级评价标准是有可能的。 The air conditioning cooling load in mild areas is greatly affected by solar radiation,In the case of not deliberately improving the thermal performance of building envelope or high cost of improving the thermal performance of building envelope,By selecting the structural characteristics and material characteristics of the window Including transparent curtain wall,It is possible to reduce the air conditioning load and finally reach the three-star green building evaluation standard.
作者 曾征 Zeng Zheng(Yunnan Design Institute Group Co.,Ltd,Kunming,650228)
出处 《制冷与空调(四川)》 2021年第4期569-573,共5页 Refrigeration and Air Conditioning
关键词 绿色建筑 评价标准 三星级 太阳辐射室内得热量 围护结构热工性能 空调负荷 Green building Evaluation criterion three-star level Room heat gain by solar radiation Thermal performance of building envelope Air conditioning load