期刊文献+

空气源热泵-电磁能耦合供热系统模拟研究 被引量:4

Simulation of Air Source Heat Pump Coupling Electromagnetic Energy Heating System
下载PDF
导出
摘要 采暖问题始终是社会关注的热点问题,能源使用效率低是制约采暖的主要因素之一。空气源热泵是一种高效清洁能源,其缺点为运行能效受冬季室外低温影响产生结霜现象,进而影响机组运行。通过TRNSYS模拟软件对空气源热泵与电磁能耦合的供热系统进行模拟研究,系统形式为空气源热泵与电磁加热器并联,耦合供热系统的采暖季平均COP为2.1,供暖水温达到45℃以上。结果表明,耦合供热系统的运行效果优于单一能源。此耦合供热系统供热效果良好,并为解决空气源热泵在严寒冬季停止运行的问题提供技术参考。 Energy is the cornerstone of social development.In recent years,people’s demand for energy is gradually increasing.Heating has always been a hot issue of social focus.Low energy efficiency is one of the main factors restricting heating.Air source heat pump is a kind of high efficiency energy and it is a clean and pollution-free energy.Its disadvantage is that the operation energy efficiency is affected by the outdoor low temperature in winter,resulting in frosting phenomenon,which affects the operation of the unit.The heating system of air source heat pump coupling electromagnetic energy is simulated by TRNSYS software.The average COP of the coupled heating system is 2.1 in heating season,and the heating water temperature is above 45℃.The results show that the operation effect of coupled heating system is better than that of single energy.The coupled heating system has fine effect in the field of heating and provides technical reference for solving the problem of air source heat pump stopping operation in severe cold winter.
作者 冯国会 刘彦廷 李旭林 刘家森 FENG Guo-hui;LIU Yan-ting;LI Xu-lin;LIU Jia-sen(School of Municipal and Environmental Engineering,Shenyang Jianzhu University,Shenyang 110168,China)
出处 《建筑节能(中英文)》 CAS 2021年第8期139-144,共6页 Building Energy Efficiency
基金 “十三五”国家支撑计划资助项目(2018YFD1100705-02)。
关键词 空气源热泵 电磁能 耦合供热系统 模拟研究 TRNSYS air source heat pump electromagnetic energy coupled heating system research on simulation TRNSYS
  • 相关文献

参考文献7

二级参考文献73

共引文献101

同被引文献40

引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部