摘要
地下水池结构在高水(地下水)工况组合下的内力计算一直是工程设计的重点和难点。由于处理工艺日益复杂、处理规模不断扩大,作为承载水处理骨架的水池结构设计也日趋复杂。常规的手算或简单的电算程序已不能满足工程设计需要。作为结构设计工程师,选用计算结果合理安全、建模效率高的软件尤为重要。论文采用目前市政水处理行业使用较多的软件进行高水工况下地下水池基础底板的计算对比,希望与从事水池结构设计的同行进行探讨,为初入者提供借鉴参考。
The internal force calculation of underground pool structure under high water(underground water)condition combination has always been the focus and difficulty of engineering design.Due to the increasing complexity of the treatment process and the continuous expansion of the treatment scale,the structural design of the water tank as the water treatment framework is becoming more and more complex.Conventional manual calculation or simple computer program can not meet the needs of engineering design.As a structural design engineer,it is particularly important to choose software with reasonable and safe calculation results and high modeling efficiency.This paper uses the current municipal water treatment industry used more software to calculate and compare the foundation slab of underground pool under high water condition,hoping to discuss with colleagues who have been engaged in pool structure design,so as to provide reference for beginners.
作者
蒋志文
JIANG Zhi-wen(Guangdong Architectural Design&Research Institute Co.Ltd.,Guangzhou 510150,China)
出处
《工程建设与设计》
2021年第15期10-12,共3页
Construction & Design for Engineering