摘要 介绍了雅培Alinity i全自动化学发光免疫分析仪的优势及重要性,统计了该仪器使用以来的常见报警代码信息,详细列出了6种常见故障的报警信息,分析了故障原因并给出了具体处理方法,为该仪器维修与管理提供了参考。 The advantages and importance of Abbott Alinity i Chemiluminescence Immunoassay Analyzer were introduced.Six common fault alarm codes of the analyzer during application were summarized,and the causes for the alarm were analyzed and some countermeasures were put forward.References were provided for the maintenance and management of the analyzer.