期刊文献+

Study on grid adaptability testing methodology for wind turbines 被引量:5

原文传递
导出
摘要 The use of wind power has grown rapidly in recent years.Wind power is a clean source of energy,but can have negative impacts on the distribution grid.The influence of large-scale wind power integration on the safe and stable operation of a power system cannot be ignored.It is necessary and urgent to achieve grid adaptability for wind turbines in China.Using a 35 kV/6 MVA grid simulator,the performance of a grid is investigated by simulation.Typical grid disturbances such as voltage deviation,frequency fluctuation,voltage unbalance,and distortion can be simulated.A grid adaptability testing methodology was developed and applied to a doubly fed wind turbine with a focus on analyzing real test data to ascertain its three-phase voltage unbalance adaptability,which was successfully demonstrated.The methodology can also be used to guide other grid adaptability tests.
出处 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2013年第1期81-87,共7页 现代电力系统与清洁能源学报(英文)
  • 相关文献

同被引文献57

  • 1李建林,许洪华.风力发电中的电力电子变流技术[M].北京:机械工业出版社,2009. 被引量:7
  • 2刘芙蓉,康勇,段善旭,王志峰,王辉.主动移频式孤岛检测方法的参数优化[J].中国电机工程学报,2008,28(1):95-99. 被引量:97
  • 3BROCHU J, LAROSE C, GAGNON R. Validation of single- and multiple-machine equivalents for modeling wind power plants[J]. IEEE Trans on Energy Conversion, 2011, 26 (2) : 532-541. 被引量:1
  • 4ASMINE M, BROCHU J, FORTMANN J, et al. Model validation for wind turbine generator models[J]. IEEE Trans on Power Systems, 2011, 26(3): 1769-1782. 被引量:1
  • 5KENNEDY J M, FOX B, LITTLER T, et al. Validation of fixed speed induction generator models for inertial responseusing wind farm measurements [J]. IEEE Trans on Power Systems, 2011, 26(3): 1454-1461. 被引量:1
  • 6ROGDAKIS G, GARCIA-VALLE R, ARANA I. Transient model validation of fixed-speed induction generator using wind farm measurements[J]. IEEE Trans on Power Systems, 2012, 27(1) : 564-571. 被引量:1
  • 7TRILLA L, GOMIS-BELLMUNT O, JUNYENT-FERRE A, et al. Modeling and validation of DFIG 3 MW wind turbine using field test data of balanced and unbalanced voltage sags[J]. IEEE Trans on Sustainable Energy, 2011, 2(4): 509-519. 被引量:1
  • 8KAMH M Z, IRAVANI R. Three-phase steady-state model of type-3 wind generation unit: Part Ⅱ model validation and applications[J]. IEEE Trans on Sustainable Energy, 2012, 3(1) : 41-48. 被引量:1
  • 9MULJADI E, ELLIS A. Validation of wind power plant models [C]// IEEE Power and Energy Society General Meeting, July 20-24, 2008, Pittsburgh, USA. 被引量:1
  • 10PIWKO R J, MILLER N W, MACDOWELL J M. Field testing and model validation of wind plants[C]// IEEE Power and Energy Society General Meeting, July 20-24, 2008, Pittsburgh, USA. 被引量:1