摘要 对一起初步认定为监盘、巡检和消缺管理不到位及热工逻辑不完.善造成的锅炉低温过热器吹损泄漏事件进行深入调查,通过爆口宏观形貌、管子和防磨瓦吹损痕迹、吹灰系统设备状况等分析,判断这起吹损泄漏事件还与吹灰系统存在蒸汽严重带水、吹灰器压力长期未整定等因素有关,并在此基础上,提出相应的措施,指导电厂进一步防范锅炉受热面吹损泄漏,同时,整个深入分析过程对类似的锅炉泄漏失效分析也具有一定的借鉴意义。 Based on the analysis of the macroscopic appearance of the blast opening,the trace of pipe and anti-wear tile blowing and the condition of the equipment of the soot-blowing system,concluded that the leakage event is also related to the serious water-carrying of steam in the soot blowing system and the long-term un in the soot blowing system,and on this basis,the corresponding measures are put forward to guide the power plant to further prevent the leakage of the boiler from blowing damage on the hot surface.At the same time,the whole depth analysis process also has the similar boiler leakage failure analysis.
作者 陈永生 Chen Yongsheng(Fujian Huadian Electric Power Engineering Corporation Limited,Fuzhou 350003)
出处 《中国特种设备安全》 2021年第6期81-84,88,共5页 China Special Equipment Safety
关键词 锅炉 低温过热器 蒸汽吹灰器 吹损 疏水 Boiler Low-temperature superheater Steam sootblower Blow loss Drainage
  • 相关文献

参考文献2

  • 1姚婧..超超临界锅炉受热面状态吹灰研究[D].长沙理工大学,2013:
  • 2陈宝康..电站锅炉受热面污染监测及优化吹灰的理论与实验研究[D].华北电力大学,2004: