摘要
研究利用水质净化厂净化后的城市中水对济南产业金融区区域供冷制冷机组进行冷却,并从工程投资、运行费用,综合成本等方面与常规冷却塔方案进行对比分析,对比可知利用城市中水优于建设常规冷却塔。利用城市中水对机组进行冷却,具有冷却水温度低、水源稳定、绿色环保、机组效率高等优点。
This paper studies the use of urban water purified by the water quality purification plant to cool the cooling unit of Jinan Industrial Financial District, and makes a comparative analysis of the project investment, operation cost,comprehensive cost and other aspects with the conventional cooling tower scheme. The comparison shows that the use of urban water is better than the construction of conventional cooling tower. It has the advantages of low cooling water temperature, stable water source, green environment protection and higher efficiency.
作者
王磊
王茂盛
蔡振兴
杨敏华
WANG Lei;WANG Mao-shen;CAI Zhen-xing;YANG Min-hua(Jinnan Municipal Engineering Design&Research Institute(Group)Co.,Ltd.)
出处
《建筑热能通风空调》
2021年第3期60-63,5,共5页
Building Energy & Environment
关键词
城市中水
区域供冷
制冷机组
冷却水
urban water
district cooling
refrigeration units
cooling water