摘要
碘吸附值是衡量活性炭质量优劣的重要指标,该实验以GB/T 12496.8—2015中(150±5)℃烘箱法为参考,用卤素水分测定仪HX204确定木质活性炭快速检测方法主参数为温度130℃,加热模式标准,关机模式1 mg/32 s。用卤素水分测定仪测定的水分计算干基碘吸附值,与烘箱法测定的碘吸附值相对标准偏差为1.36%,在误差允许范围,两种方法碘吸附值无显著差异。
The iodine adsorption value is an important index to measure the quality of active carbon.Using the(150±5)℃oven method in GB/T 12496.8—2015 as a reference,the main parameters for rapid determination method of wooden activated carbon were determined by the halogen moisture analyzer HX204,which was temperature 130℃,standard heating mode,and shutdown mode 1 mg/32 s.The dry iodine adsorption value was calculated with moisture determined by the halogen moisture analyzer,and the relative standard deviation was 1.36%compared with the iodine adsorption value determined by the oven method.There were no significant differences between the two methods in the allowable range of error.
作者
袁先群
侯格妮
张敏
张丽平
杨浩
吴建霞
王莉
YUAN Xianqun;HOU Geni;ZHANG Min;ZHANG Liping;YANG Hao;WU Jianxia;WANG Li(Quality Department of Kweichow Moutai Liquor Co.,Ltd.,Renhuai 564501,China)
出处
《中国酿造》
CAS
北大核心
2021年第4期168-171,共4页
China Brewing
关键词
木质活性炭
卤素水分测定仪
水分
碘吸附值
wood activated carbon
halogen moisture analyzer
moisture
iodine adsorption value