摘要 通过金相显微镜、扫描电镜和拉伸性能测试,分析了废水处理用TA10弯管的失效原因。结果表明:TA10弯管内壁氧化严重,在较高温度下弥散相消失导致其力学性能下降,并在高压流体冲刷作用下发生冲蚀,从而导致弯管薄弱区发生破裂。 Through metallographic microscope,scanning electron microscope and tensile performance testing,the reasons for the failure of TA10 elbows for waste water treatment were analyzed.The results show that the inner wall of TA10 elbow was seriously oxidized.The disappearance of dispersion phase at higher temperature resulted in the decrease of elbow′s mechanical properties.And erosion occurred under the action of high pressure fluid flushing,leading to the cracking of the weakened area of the elbow.
作者 李丰博 崔少平 李宁 王娅辉 LI Fengbo;CUI Shaoping;LI Ning;WAN Yahui(Xi'an United Vessel Manufacture Co.,Ltd.,Xi'an 710201,China)
出处 《腐蚀与防护》 CAS 北大核心 2021年第3期68-72,共5页 Corrosion & Protection
关键词 TA10弯管 腐蚀 失效原因 TA10elbow corrosion failure reason
  • 相关文献

参考文献4

二级参考文献17

  • 1中国腐蚀与防护学会.三峡工程金属结构防腐蚀问题的调查研究与分析报告[M].北京,1995.. 被引量:1
  • 2张文保.试论船闸金属结构的腐蚀防护.中国第八届表面保护技术暨第二次三峡工程防腐蚀技术交流会论文集[M].宜昌,1997.. 被引量:1
  • 3宜昌市环境保护监测站.葛洲坝船闸处长江水质监测报告[M].,1995.. 被引量:1
  • 4朱日彰(译).腐蚀与防护技术基础[M].北京:冶金工业出版社,1987.. 被引量:2
  • 5左景伊(译).腐蚀工程[M].北京:化学工业出版社,1987.. 被引量:1
  • 6[1]Schmitt G, et al. Understanding localized CO2 corrosion of carbon steel from physical properties of iron carbonate scales[A]. Corrosion/99[C], paper No.38. Houston: NACE, 1999. 被引量:1
  • 7[2]Ramachandran S, Campbell S, Ward M B. The interactions and properties of corrosion inhibitors with byproduct layers[A]. Corrosion/2000[C], paper No.25. Houston: NACE, 2000. 被引量:1
  • 8林海潮,人民长江,1995年,26卷,5增 被引量:1
  • 9宜昌市环境保护监测站,葛洲坝船闸处长江水质监测报告,1995年 被引量:1
  • 10中国腐蚀与防护学会,三峡工程金属结构防腐蚀问题的调查研究与分析报告 [R],1995年 被引量:1

共引文献174

同被引文献23

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部