摘要
依据JJG 762-2007《引伸计》检定规程,使用引伸计标定器校准YYU-10/50型引伸计的系统示值,参照JJF 1059.1-2012《测量不确定度评定与表示》计量技术规范,分析了系统示值结果不确定度的来源,并进行了综合评定。
According to the verification regulation for extensometer of JJG 762-2007,the system indication value of YYU-10/50 extensometer is calibrated by calibrator of extensometer.Refer to the evaluation and expression of uncertainty in measurement of JJF 1059.1-2012,the source of uncertainty of indication result of the system is analyzed,and the comprehensive evaluation is finished.
作者
王增光
范新超
王菁钰
张冰
王贵勇
Wang Zengguang;Fan Xinchao;Wang Jingyu;Zhang Bing;Wang Guiyong(NCS Testing Technology Co.,Ltd.,Beijing 100094,China)
出处
《工程与试验》
2021年第1期45-46,共2页
Engineering and Test
关键词
引伸计
校准
不确定度
extensometer
calibration
uncertainty