提高严寒地区SF_(6)充气效率设备的研制

Development of Equipment for Improving SF Charging Efficiency in Severe Cold Area
下载PDF
导出
摘要 阐述一种利用联充接头与水浴加热相结合的方法提高SF_(6)充气效率的设备。实践表明,使用该充气设备能大大缩短充气时间,解决了特高压工程锡盟换流站GIS设备安装工期紧张的问题。该设备能推广至各严寒地区SF_(6)充装现场。 This paper describes a device to improve the charging efficiency of SF_(6) by using the combination of joint charging and water bath heating. The practice shows that the inflation time can be greatly shortened by using the inflation equipment, which solves the problem of short installation period of GIS equipment in Ximeng converter station of UHV project. The equipment can be extended to SF_(6) filling sites in cold regions.
作者 顾杰峰 张锴 钱佳琪 刘提 GU Jiefeng;ZHANG Kai;QIAN Jiaqi;LIU Ti(Construction Branch of State Grid Zhejiang Electric Power Co.,Ltd.,Zhejiang 310020,China;Economic and Technological Research Institute of State Grid Zhejiang Electric Power Co.,Ltd.,Zhejiang 310020,China)
出处 《集成电路应用》 2021年第3期52-53,共2页 Application of IC
关键词 SF_(6) 充气效率 特高压工程 严寒地区 SF_(6) inflation efficiency UHV engineering severe cold area