摘要 AIM:To compare the objective visual quality after implantation of a toric intraocular lens(IOL)in order to correct moderate or high corneal astigmatism at the one year postoperative follow-up.METHODS:From December 2017 to June 2018,66 patients(90 eyes)with simple age-related cataract with regular corneal astigmatism greater than 1.5 D were enrolled in this prospective self-control study.The patients were implanted with Proming?toric IOL(model:AT3 BH-AT6 BH).The subjects were divided into moderate astigmatism group(46 eyes,1.5-2.5 D)and high astigmatism group(44 eyes,>2.5 D).The uncorrected distance visual acuity,residual astigmatism and axial position of IOL were observed before operation,3,6 mo and 1 y after operation.Modulation transfer function cutoff(MTF cutoff),Strehl ratio(SR),object scatter index(OSI)were observed by OQAS II to evaluate the objective visual quality of patients.RESULTS:There was no significant difference in UCVA,residual astigmatism,axial deviation,MTF cutoff,SR and OSI between moderate and high astigmatism group(all P>0.05).After 3 mo,UCVA,MTF cutoff and SR were significantly increased(all P<0.05),residual astigmatism and OSI were significantly decreased(all P<0.05).After 3 mo,all the indexes remained stable.CONCLUSION:Proming toric IOL can effectively treat age-related cataract patients with moderate-to-high regular corneal astigmatism,correcting corneal astigmatism,improving UCVA,ensuring long-term stability in the capsule,and providing patients with better visual quality.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第2期245-249,共5页 国际眼科杂志(英文版)
  • 相关文献

参考文献12

二级参考文献123

  • 1李斌,陈世豪,王勤美,牛燕.近视激光手术人群角膜直径的调查和分析[J].眼科新进展,2006,26(5):383-385. 被引量:9
  • 2廉井财,周正申,张雷,朱彩红,孟浩,王康孙.前房型人工晶状体植入治疗高度近视眼[J].中华眼科杂志,2006,42(8):709-713. 被引量:12
  • 3赵堪兴,杨培增.眼科学.第7版.北京:人民卫生出版社.2008.75. 被引量:51
  • 4KHALAJ M, BARIKANI A, GHASEMI H. Eye disorders in old people [ J ]. Glob J Health Sci,2012,5 ( 1 ) : 79 - 86. 被引量:1
  • 5CHENG LS, TSAI CY, TSA1 R J, et al. Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurement [ J ]. Acta Ophthalmol, 2011,89(5) :417 -422. 被引量:1
  • 6JIN H, LIMBERGER lJ, EHMER A, et al. Impact of axis misalignment of toric intraocular lenses on refractive outcomes after cataract surgery [ J ]. J Cataract Refract Surg, 2010, 36 ( 12 ) : 2061 - 2072. 被引量:1
  • 7WHANG WJ, BYUN YS, JOO CK. Comparison of refractive outcomes using five devices for the assessment of preoperative corneal power [ J ]. Clin Experiment Ophthalmol, 2012,40 ( 5 ) : 425 - 432. 被引量:1
  • 8MAS D,ESP1NOSA J, DOMENECH B, et al. Correlation between the dioptric power, astigmatism and surface shape of the anterior and posterior corneal surfaces [ J ]. Ophthal Physl Pot, 2009,29 (3) :219 -226. 被引量:1
  • 9KOCH DD, ALI SF, WEIKERT MP, et al. Contribution of posterior corneal astigmatism to total corneal astigmatism [ J 1. J Cataract Refract Surg,2012,38 (12) :2080 - 2087. 被引量:1
  • 10CAREY PJ, LECCISOTTI A, MCGILLIGAN VE, eta|. Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation [ J ]. J Cataract Refract Surg,2010,36(2) :222 -229. 被引量:1

共引文献83

同被引文献8

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部