摘要
为提高某装备激活装置的输出感应电动势,根据激活装置结构和原理,从减小衔铁拨动时间着手,针对衔铁构型进行优化,提出了三种衔铁构型改进方案,并通过Ansys Maxwell二维和三维电磁仿真试验,从中挑选出了最优方案,并验证了该方案的可行性。
In order to increase the output induced electromotive force of a certain equipment activation device,three armature configuration improvements are proposed based on the structure and principle of the activation device.To reduce the armature toggle time,the optimal scheme was selected and the feasibility of the scheme was verified through Ansys Maxwell simulation.