期刊文献+

现浇混凝土空心楼盖施工质量检测与分析 被引量:7

Construction quality inspection and analysis of cast-in-situ concrete hollow floor
下载PDF
导出
摘要 针对空心楼盖的内部构造特点,提出了以天线频率为1 500MHz的雷达检测薄板及分析方法,该方法能较准确地确定空心楼盖下翼缘薄板因振捣不充分而导致的不密实区的位置及延伸范围,可供类似工程采用。检测结果表明,空心楼盖因芯模阻挡,极易造成下翼缘薄板不密实、空腔等严重的混凝土施工质量问题,现场施工时应严格监管施工过程。同时,有限元分析结果表明,这种下翼缘薄板不密实和空腔等施工质量问题将显著增加结构变形和应力,严重影响结构的受力性能,亟需进行加固处理以确保结构安全。 Aiming at the internal structural characteristics of the hollow floor, a radar detection and analysis method for the thin slab with an antenna frequency of 1 500 MHz was proposed. This method can more accurately determine the uncompacted location and extension of the lower flange thin slab of the hollow floor caused by the inadequate vibration, and it can be used in similar projects. The test results show that the hollow floor is blocked by mandrels, it is easily lead to serious concrete construction quality problems such as uncompacted area and cavity of the lower flange thin slab. So construction progress should be strictly supervised on the site of construction. At the same time, the finite element analysis results show that the construction quality problem such as uncompacted area and cavity of the lower flange thin slab will significantly increase the deformation and stress of the structure, and have seriously negative effect on the mechanical properties of the structure. Therefore, reinforcement treatment is urgently needed to ensure the safety of the structure.
作者 姚帅 吕伟荣 丁时宝 卢倍嵘 石卫华 YAO Shuai;Lü Weirong;DING Shibao;LU Beirong;SHI Weihua(School of Civil Engineering,Hunan University of Science and Technology,Xiangtan 411201,China)
出处 《建筑结构》 CSCD 北大核心 2020年第24期99-103,共5页 Building Structure
基金 国家自然科学基金面上项目(51578235,51678234) 湖南省自然科学基金项目面上项目(2018JJ2129)。
关键词 空心楼盖 现浇混凝土 空腔 地质雷达 芯模 薄板 施工质量检测 hollow floor cast-in-situ concrete cavity geological radar mandrel thin slab construction quality inspection
  • 相关文献

参考文献4

二级参考文献12

共引文献38

同被引文献40

引证文献7

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部