期刊文献+

轨道交通杂散电流对武汉燃气管道干扰的波动规律 被引量:7

Fluctuation Regularity of Stray Current Interference from Rail Transit to Wuhan Gas Pipelines
下载PDF
导出
摘要 对武汉轨道交通动态直流干扰下的燃气管道的管地电位进行了24h连续监测,对其干扰进行风险评估,并利用傅里叶变换对数据进行频域分析,统计了杂散电流干扰下管地电位波动的频率、分布、幅值等动态特征。结果表明:燃气管道处于高直流干扰风险区的有20处,低风险区域的有7处;受有轨电车干扰管地电位波动存在明显间歇性,一个间歇期为130~140s,而地铁无明显间歇期;各轨道交通线路引起的波动频率不尽相同,但是50%以上的波动频率集中在0.005~0.03Hz。 The pipe-to-soil potentials of the gas pipelines under the dynamic DC interference of Wuhan rail transit were continuously monitored for 24 h.The interference risk was evaluated and Fourier transform was used to analyze the data in frequency domain.The frequency,distribution,amplitude and other dynamic characteristics of pipe-to-soil potential fluctuation under the interference of stray current were analyzed.The results show that there were 20 points of gas pipelines in high DC interference risk zone and 7 points in low risk zone.The fluctuation of pipe-to-soil potentials under the interference of trams was intermittent,an entire intermittency period was 130-140 s,but it was not intermittent under the interference of metros.Though the fluctuation frequency caused by various rail transit lines was different,more than 50%fluctuation frequency was concentrated in 0.005-0.03 Hz.
作者 肖嵩 姜子涛 童清福 王宏新 李勃聪 陈程 XIAO Song;JIANG Zitao;TONG Qinfu;WANG Hongxing;LI Bocong;CHEN Cheng(Wuhan Natural Gas Co.,Ltd.,Wuhan 430030,China;China University of Petroleum(Beijing),Beijing 102249,China;Safetech Research Institute Co.,Ltd.,Beijing 100083,China)
出处 《腐蚀与防护》 CAS 北大核心 2020年第12期37-43,共7页 Corrosion & Protection
关键词 轨道交通 杂散电流 燃气管道 傅里叶变换 波动特征 rail transit stray current gas pipeline Fourier transform fluctuation characteristic
  • 相关文献

参考文献5

二级参考文献43

  • 1胡士信.煤气管道杂散电流干扰及排流保护[J].煤气与热力,1996,16(1):23-29. 被引量:6
  • 2王崇林,马草原,王智,潘春德,王雨扬.地铁直流牵引供电系统杂散电流分析[J].城市轨道交通研究,2007,10(3):51-53. 被引量:20
  • 3秦国治,丁量棉,田志明.管道防腐蚀技术[M].北京:化学工业出版社,2004. 被引量:3
  • 4Zakowski K K, Sokolski W. 24-hour characteristic of interaction on pipelines of stray currents leaking from tram tractions[J]. Corrosion Science, 1999,41 (11) : 2103-2108. 被引量:1
  • 5Luca Ardizzon, Paolo Pinato, Dario Zaninelli. Electric traction and electrolytic corrosion: a software tool for stray current calculation[C]//2003 IEEE PES Transmission and Distribution Conference and Exposition, Dallas TX USA: 2003 : 550-551. 被引量:1
  • 6Levin S I, Kharionovsky V V. Causes and frequency of failures on gas mains in the USSR PIPE[J].Pipes Pipelines International, 1993,38(4) : 7-8. 被引量:1
  • 7Ian Cotton, Pete Aylott, Petra Ernst. Stray current control in DC mass transit systems[J]. IEEE Rransaction on Vehicular Technology March, 2005, 54 (2) 722. 被引量:1
  • 8SYJ4020-1988.埋地钢质管道石油沥青防腐层施工及验收规范[S]. 被引量:1
  • 9Darowicki K, Krakowiak S, Slepski P. Evaluation of pitting corrosion by means of dynamic electrochemical impedance spectroscopy [J].Electrochimica, 2004, 49 (17):2909-2918. 被引量:1
  • 10于伟松,杨兴山,韩连祥,等.城市轨道交通供电系统设计原理与应用[M].成都:西南交通大学出版社,2008. 被引量:8

共引文献61