期刊文献+

磁共振波谱联合MRI多参数技术组合对提高前列腺癌诊断特异度的价值探讨 被引量:12

The high-specificity diagnostic value of the magnetic resonance spectroscopy combined multi-parameter scanning in the prostate cancer
下载PDF
导出
摘要 目的分析磁共振波谱成像联合常用多参数技术在前列腺癌中的诊断价值。方法选取在我院进行治疗的33例确诊为前列腺癌患者,以病理穿刺确诊前列腺增生33例为对照组。两组患者穿刺前均进行磁共振多参数常规扫描和波谱扫描。影像学结果和病理穿刺结论对比分析。结果常规MRI多参数技术组合方案确诊前列腺癌27例。上述方法再联合波谱扫描后确诊前列腺癌31例。前者扫描准确率和特异度分别为80.30%和78.71%。后者准确率和特异度分别为90.91%和92.42%,差异具有统计学意义(P<0.05).磁共振波谱扫描中,(Cho+Cre)/Cit>0.98为阳性。在前列腺增生中波谱扫描所得(Cho+Cre)/Cit比值低于前列腺癌比值。结论MRI常用多参数扫描在对前列腺癌诊断存在不足之处,其诊断准确率和特异度低于磁共振波谱联合MRI常规多参数扫描方案。 Objective To analyze the value of the magnetic resonance spectroscopy combined multi-parameter scanning and explore the value of mrs.Methods We selectd 33 patients with a definite diagnosis of prostate cancer and 33 patients with making a definite diagnosis of benign prostatic hyperplasia.All patients were diagnosed with MRI from February 2019 to December 2019 in our hospital.The MRI results were analyzed with the pathological biopsy results.Results The specificity and accuracy of the multi-parameter scanning were 78.71%,80.30%.The latter was 90.91%,92.42%.Respectively,the differences were statistically significant(P<0.05).In the scanning of MRS,the mean ratio of(Cho+Cre)/Cit was>0.98.Conclusion The data of multi-parameter scanning are lower than the specificity and accuracy of MRS canbined MRI nuti-parameter scanning.The ratio of(Cho+Cre)/Cit in benign prostatic hyperplasia is lower than the ratio of prostate canner.
作者 李雯 于天依 郭依廷 LI Wen;YU Tianyi;GUO Yiting(Department of Radiology, The Second Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250001, P.R.China;Department of Radiology, Provincial Hospital Affilicated to Shandong First Medical Uiversity, Jinan 250021, P.R.China)
出处 《医学影像学杂志》 2021年第1期83-86,共4页 Journal of Medical Imaging
关键词 磁共振成像 多参数扫描 磁共振成像波谱扫描 前列腺癌 前列腺增生 Magnetic resonance imaging Multi-parameter scanning Magnetic resonance spectroscopy Prostate cancer Benign prostatic hyperplasia
  • 相关文献

参考文献6

二级参考文献47

  • 1彭涛,伍兵,肖建明.磁共振波谱与扩散加权成像技术诊断前列腺癌的比较研究[J].四川大学学报(医学版),2013,44(5):827-831. 被引量:6
  • 2王霄英,周良平,丁建平,王刚,肖江喜,蒋学祥.中国正常成年男性前列腺的MRS定量分析[J].中国医学影像技术,2003,19(5):576-578. 被引量:24
  • 3张学琴,王霄英,陆健,缪小芬,郭雪梅,李飞宇,刘婧,蒋学祥.前列腺中央腺体偶发癌与中央腺体癌的MR扩散加权成像[J].放射学实践,2011,26(1):66-69. 被引量:10
  • 4黄嵘,王霄英,何云峰,李飞宇,许玉峰,刘鹏程,蒋学祥.前列腺外周带癌的MRI 6分区定位诊断研究[J].中华放射学杂志,2006,40(7):684-689. 被引量:2
  • 5Torre LA,Bray F,Siegel RL,et al.Global cancer statistics,2012.CA Cancer J Clin,2015,65(2):87-108. 被引量:1
  • 6Le Nobin J,Rosenkrantz AB,Villers A,et al.Image guided focal therapy for magnetic resonance imaging visible prostate cancer:defining a 3-dimensional treatment margin based on magnetic resonance imaging histology Co-registration analysis.J Urol,2015,194(2):364-370. 被引量:1
  • 7Hegde JV,Mulkern RV,Panych LP,et al.Multiparametric MRI of prostate cancer:an update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer.J Magn Reson Imaging,2013,37(5):1035-1054. 被引量:1
  • 8Cho E,Chung DJ,Yeo DM,et al.Optimal cut-off value of perfusion parameters for diagnosing prostate cancer and for assessing aggressiveness associated with Gleason score.Clin Imaging,2015,39(5):834-840. 被引量:1
  • 9Li B,Cai W,Lv D,et al.Comparison of MRS and DWI in the diagnosis of prostate cancer based on sextant analysis.J Magn Reson Imaging,2013,37(1):194-200. 被引量:1
  • 10Langer DL,van der Kwast TH,Evans AJ,et al.Prostate cancer detection with multi-parametric MRI:logistic regression analysis of quantitative T2,diffusion-weighted imaging,and dynamic contrast-enhanced MRI.J Magn Reson Imaging,2009,30(2):327-334. 被引量:1

共引文献160

同被引文献105

引证文献12

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部