摘要
数据中心的机房空调群是机房节能减排的重点对象。提出利用服务器与空调通信数据来实现服务器内部温度控制,达到按需供冷的控制方法。数据汇集服务器具有与机房服务器通信的功能,以获得其负责区域内所有服务器、网络设备的温度、总功率等实时数据并传输至空调主控制器,空调主控制器按服务器的实际冷却需求来调节空调的供冷量输出,在保证服务器设备安全的前提下最大限度地提高机房环境温度,以实现节能。
The air conditioning group in the data center is the key object of energy conservation and emission reduction.This paper presents a method to control the internal temperature of the server by using the communication data between the server and the air conditioner to achieve on-demand cooling.The data collection server has the function of communicating with the server room to obtain the real-time data such as the temperature and total power of all servers and network equipment in its responsible area and transmit them to the main controller of the air conditioner.According to the actual cooling demand of the server,the main controller of the air conditioner adjusts the cooling output of the air conditioner to maximize the ambient temperature of the computer room on the premise of ensuring the safety of the server equipment, so as to achieve energy saving.
作者
邹亮平
ZOU Liangping(Nanjing Ucase Software Co.,Ltd.,Nanjing 210019)
出处
《现代制造技术与装备》
2020年第12期117-118,共2页
Modern Manufacturing Technology and Equipment
关键词
数据中心
机房空调
节能减排
data center
computer room air conditioning
energy saving and emission reduction