期刊文献+

植入Akreos MI60人工晶状体后客观视觉质量的研究

Research on objective visual quality after Akreos MI60 implantation
原文传递
导出
摘要 目的评估Akreos MI60人工晶状体植入术后的视觉质量.方法前瞻性病例对照研究.收集济南市第二人民医院2017年2月至8月白内障65例(65眼)行超声乳化人工晶状体植入术,随机分为两组,A组植入博士伦Akreos MI60人工晶状体;B组植入博士伦Akreos Adapt普通人工晶状体.利用双通道客观分析系统(OQAS)分析术后3个月客观视网膜成像质量指标.结果两组之间术前基线资料对比差异无统计学意义(P>0.05).术后3个月时,A组视力(BCVA,LogMAR)为0.02±0.09,优于B组的0.07±0.12(t=1.952,P=0.005);术后散光A组为(0.83±0.19)D,优于B组的(1.19±0.28)D(t=6.137,P<0.001).A组客观散射指数为1.79±0.95,优于B组的2.80±1.87(t=2.803,P=0.006);A组斯特尔比值优于B组(t=2.248,P=0.034).结论博士伦Akreos MI60人工晶状体植入后视功能指标优于普通人工晶状体植入者. Objective To evaluate the visual quality after Akreos MI60 intraocular lens implantation.Methods This was a prospective case-control study.A total of 65 eyes of 65 cases with age-related cataract who underwent phacoemulsification combined with IOL implantation from Jan.2017 to Aug.2017.in the Second People's Hospital of Jinan were collected in this study.The patients were randomly divided into two groups.Group A was implanted with Bausch&Lomb Akreos MI60 IOL.Group B was implanted with Bausch&Lomb Akreos Adapt IOL.The dual-channel objective analysis system(OQAS)was used to analyze objective retinal imaging quality indexes at 3 months after surgery.Results The difference in preoperative baseline data between two groups was not statistically significant(P>0.05).At 3 months postoperatively,the visual acuity(BCVA,LogMAR)of group A was 0.02±0.09,which was better than 0.07±0.12 of group B(t=1.952,P=0.005).Postoperative astigmatism in group A was(0.83±0.19)D,which was better than(1.19±0.28)D in group B(t=6.137,P<0.001).The objective scattering index of group A was 1.79±0.95,which was better than 2.80±1.87 of group B(t=2.803,P=0.006).The strehl ratio of group A was better than that of group B(t=2.248,P=0.034).Conclusion Bausch&Lomb Akreos MI60 intraocular lens has better visual function than ordinary intraocular lens.
作者 李彬 仲洁 王晶 毕超 张苗苗 Li Bin;Zhong Jie;Wang Jing;Bi Chao;Zhang Miaomiao(Department of Ophthalmology,The Second People's Hospital of Jinan 250001,China;Department of Ophthalmology,Yucheng People's Hospital,Shandong 251200,China)
出处 《中华眼外伤职业眼病杂志》 2020年第12期956-960,共5页 Chinese Journal of Ocular Trauma and Occupational Eye Disease
关键词 晶状体 人工 AKREOS MI60 分析 质量 视觉 客观 Lens,intraocular,Akreos MI60 Analysis,quality,visual,objective
  • 相关文献

参考文献8

二级参考文献78

  • 1董喆,王宁利,朱思泉,王军,王开杰,贾力蕴,赵世强,王小兵.睫状肌收缩与可折叠人工晶状体植入眼伪调节力的关系[J].中华眼科杂志,2007,43(2):99-103. 被引量:8
  • 2Atchison DA. Design of aspheric intraocular lenses [ J]. Ophthal Physiol Opt, 1990,11 : 137-146. 被引量:1
  • 3Applegate RA, Thibos LN, Hilmantel G. Optics of aberroscopy and supervision [ J ] . J Cataract Refract Surg, 2001,27 : 1093- 1107. 被引量:1
  • 4McLellan JS, Marcos S, Prieto PM, et al. Imperfect optics may be the eyes defense against chromatic blur [ J ]. Nature, 2002,417 : 174-176. 被引量:1
  • 5Zhao H, Mainster MA. The effect of chromatic dispersion on pseudophakic optical performance[J]. BrJ Ophthalmol,2007,91 : 1225-1229. 被引量:1
  • 6Negishi K, Ohnuma K, Hirayama N, et al. Effect of chromatic aberration on contrast sensitivity in pseudophakic eyes [ J ]. Arch Ophthalmol, 2001, 119 : 1154-1158. 被引量:1
  • 7Jose RM, Bender LE, Boyce JF, et al Correlation between the measurement of posterior capsule opacification severity and visual function testing[J]. J Cataract Refract Surg,2005,31:534-542. 被引量:1
  • 8Erie JC, Bandhauer MH, McLaren JW. Analysis of postoperative glare and intraocular lens design[ J]. J Cataract Refract Surg, 2001,27:614-621. 被引量:1
  • 9Artal P,Berrio E,Guirao A,et al.Contribution of the cornea and internal surfaces to the change of ocular aberrations with age. Journal of the Optical Society of America A: Optics, Image Science and Vision . 2002 被引量:2
  • 10A. Debois,Y. Nochez,C. Bezo,D. Bellicaud,P.-J. Pisella.Précision réfractive et qualité de vision objective après implantation torique pseudophaque[J]. Journal Francais d’Ophtalmologie . 2012 (8) 被引量:1