期刊文献+

两种试剂应用在全自动血凝仪定量检测D-二聚体时对检测结果的影响分析

Analysis of the influence of two reagents on the results of quantitative detection of D-dimer by automatic blood coagulation analyzer
下载PDF
导出
摘要 目的:分析D-DHS试剂和传统D-Dimer试剂应用在全自动血凝仪定量检测D-二聚体时对检测结果的影响。方法:选取患者98例,根据检测试剂不同分为D-DHS组和D-Dimer组,各49例。所有患者均通过全自动血凝仪定量检测D-二聚体含量;对比两组D-二聚体含量和测定结果符合率差异。结果:D-DHS组检测D-二聚体平均含量低于D-Dimer组,差异有统计学意义(P<0.05);D-DHS组诊断符合率高于D-Dimer组,差异有统计学意义(P<0.05)。结论:D-DHS试剂和传统D-Dimer试剂在全自动血凝仪定量检测D-二聚体过程中,D-DHS试剂的诊断符合率更高。 Objective:To explore the influence of D-DHS reagent and traditional D-Dimer reagent on the results of quantitative detection of D-Dimer by automatic blood coagulation analyzer.Methods:98 patients were selected and divided into D-DHS group and D-dimer group with 49 cases in each group.The D-dimer content was detected quantitatively by automatic blood coagulation analyzer.We compared the difference of the content of D-dimer and the coincidence rate of determination results between the two groups.Results:The average content of D-dimer in D-DHS group was lower than that in D-Dimer group,the difference was statistically significant(P<0.05).In the D-DHS group,the diagnostic coincidence rate was higher than that in the D-Dimer group,the difference was statistically significant(P<0.05).Conclusion:When D-DHS reagent and traditional D-dimer reagent are used in the quantitative detection of D-dimer by automatic blood coagulation analyzer,the diagnostic coincidence rate of D-DHS reagent is higher.
作者 马静 Ma Jing(Laboratory,the Traditional Chinese Medical Hospital of Xianfeng County,Hubei Xianfeng 445600)
出处 《中国社区医师》 2021年第2期130-131,共2页 Chinese Community Doctors
关键词 D-二聚体 D-DHS试剂 D-Dimer试剂 定量检测 全自动血凝仪 诊断意义 D-dimer D-DHS reagent D-Dimer reagent Quantitative detection Automatic hemagglutination instrument Diagnostic significance
  • 相关文献

参考文献6

二级参考文献41

  • 1孔建新,姚丽娟,李洁.CA-7000血凝分析仪性能评估及临床参考范围建立[J].临床输血与检验,2011,13(3):240-244. 被引量:9
  • 2颜存粮,彭黎明,黄海雄.不同血凝分析仪检测结果的一致性研究[J].中华检验医学杂志,2008,31(1):100-103. 被引量:15
  • 3Sartori M,Cosmi B,Legnani C,et al.The Wellsrule and D-dimer for the diagnosis of isolateddistal deep vein thrombosis[J].J Thromb Haemost,2012,10(11):2264-2269. 被引量:1
  • 4Bates SM.D-dimer assays in diagnosis andmanagement of thrombotic and bleeding disorders[J].Semin Thromb Hemost,2012,38(7):673-682. 被引量:1
  • 5K h a l a f a l l a h A , J a r v i s C,Mor s e M , e t a l .Evalnation of innovance d-dimer assay forthe diagnosis of disseminated intravascularcoagulopathy in different clinical settings[J].ClinAppl Thromb Hemost,2014,20(1):91-97. 被引量:1
  • 6Luxembourg B,Schwonberg J,Hecking C,et al.Performance of five D-dimer assays for the exclusionof symptomatic distal leg Vein thrombosis[J].ThrombHaemost,2012,107(2):369-378. 被引量:1
  • 7Prisco D,Grifoni E.The role of D-Dimer testing inpatients with suspected venous thromboembolism[J].SeminThrombHemost,2009,35(1):50-59. 被引量:1
  • 8National Committee for Clinical LaboratoryStandards.Interference testing in clinicalchemistry.Approved guideline-second editionguideline.EP7-A2[C].Pennsylvania:NCCLS,2005. 被引量:1
  • 9Oude Elferink RF,Loot AE,Van De KlashorstCG,et al.Clinical evaluation of eight differentD-dimer tests for the exclusion of deep venous thrombosis in primary care patients[J].Scand JClin Lab Investn,2015,75(3):230-238. 被引量:1
  • 10Goen Herak D,Milos,M,Zadro R.Evaluation ofthe innovance D-Dimer analytical Performance[J].Clin ChemLab Med,2009,47(8):94. 被引量:1

共引文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部