期刊文献+

某水电站导叶错位报警方式存在问题与改进

Problems and Improvement of Guide Vane Dislocation Alarm Mode in a Hydropower Station
下载PDF
导出
摘要 分析了某水电站导叶错位报警方式存在的问题及处理措施,通过加装导叶摩擦信号装置对原电气二次回路进行改进与优化,同时对作业环境进行改善,提高了设备运行的可靠性和维护工作的可操作性。 The existing problems and treatment measures of the guide vane dislocation alarm mode of a hydropower station were discussed.By installing the guide vane friction signal device,the original electrical secondary circuit was improved and optimized,and the working environment was improved at the same time,which improved the reliability of equipment operation and the operability of maintenance work.
作者 刘艳梅 孙宝坤 魏源 LIU Yanmei;SUN Baokun;WEI Yuan(SDIC Gansu Xiaosanxia Power Co.,Ltd.,Baiyin 730900,China)
出处 《电工技术》 2020年第24期87-88,90,共3页 Electric Engineering
关键词 水电站 导叶摩擦装置 导叶错位 导叶摩擦信号装置 安全 经济 hydropower station guide vane friction device guide vane dislocation guide vane friction signal device safety economic
  • 相关文献

参考文献1

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部