期刊文献+

600MW超临界汽轮发电机组A、B低压转子振动异常原因分析及处理 被引量:2

Cause Analysis and Treatment of 600MW Supercritical Turbine Generator Unit Vibration
下载PDF
导出
摘要 对某电厂600MW超临界汽轮机发电机组振动问题进行了阐述,对该机组A、B低压转子异常振动的特征进行了详细分析,确定导致该机组A、B低压转子振动异常的主要原因是A、B低压转子存在质量不平衡。通过对A、B低压转子进行现场动平衡配重试验,消除了A、B低压转子的振动异常。此次分析处理经验可为同类型600MW机组提供参考和借鉴。 The paper expounds the vibration of 600MW supercritical steam turbine generator set in power plant.The characteristics of abnormal vibration of A and B low pressure rotor are analyzed in detail.The main reason for the abnormal vibration of the A and B low pressure rotor of this unit is that the low pressure rotor of A and B has the unbalance of the quality.Through field balancing test of A and B low pressure rotor,the vibration abnormality of A and B low pressure rotors was eliminated.The analysis and processing experience can provide reference and reference for the same type of 600MW units.
作者 李清 张再刚 廖小军 吴元元 程岚 汪光亮 LI Qing;ZHANG Zai-gang;LIAO Xiao-jun;WU Yuan-yuan;CHENG Lan;WANG Guang-liang(Hubei Energy Group Ezhou Power Generation Company Limited,Ezhou 436032,China)
出处 《汽轮机技术》 北大核心 2020年第6期459-461,共3页 Turbine Technology
关键词 汽轮机发电机组 低压转子 振动 动平衡 turbine low-pressure rotor vibration dynamic balancing