试验采用水加热浸取四氧化三钴中的氯离子,在离子强度调节剂硝酸钠存在下,用氯离子选择电极测定四氧化三钴中水溶性氯离子含量,试验结果表明,样品加标回收率在95.5~112%之间,相对标准偏差:≤4.5%,满足0.01%~1.0%范围内氯离子的测定。此法准确度高,操作快速、简便。
The content of water-soluble chloride ion in cobalt troxide was determined by ion selective electrode method with ionic strength modifier sodium nitrate.The test results show that the recoveries of the spiked samples are in the range of 95.5%-112%,the relative standard deviations are less than or equal to 4.5%,which meet the requirement of chloride ions determination in the range of 0.01%-1.0%.The method is accurate,fast and simple.