摘要
苏州某科技住宅小区空调系统采用地源热泵作为空调冷热源,空调系统采用热湿独立处理的形式。天棚辐射系统来消除室内显热负荷,新风采用带热回收的空调箱单独处理,室内采用地板置换送风的形式。通过全年动态负荷计算,本工程还设置了辅助风冷热泵来保证土壤全年热平衡。为类似的恒温恒湿住宅空调系统提供了参考和借鉴。
An constant temperature and humidity residential project in Suzhou used the Ground Source Heat Pump(GSHP)as the air conditioning chilled and hot source,and it’s air conditioning system is independent temperature and humidity control.The sensible heat load is taken by the ceiling radiation system,and the fresh air is handled by AHU and sent to the rooms by floor outlets.The air cooled heat pump is installed for the heat balance of ground source according to the annual dynamic load calculation report.These provide a good reference for the similar constant temperature and humidity air conditioning system design.
作者
金叶佳
丁炯
Jin Yejia;Ding Jiong
出处
《洁净与空调技术》
2020年第3期87-90,共4页
Contamination Control & Air-Conditioning Technology
关键词
地源热泵
恒温恒湿住宅
热湿独立处理
热平衡
GSHP
Constant temperature and humidity
Independent temperature and humidity control
Heat balance