以徐州市某三级甲等综合医院为例,对比一次回风热湿处理和新风深度除湿处理的过程计算,分析系统节能及全年运行经济性,确定医疗建筑新风深度除湿处理的洁净空调系统,既能满足功能需求,又能实现系统节能。
Takes a third-grade class-A general hospital in Xuzhou as an example,compares the process calculation of air treatment mode for primary return air-conditioning system and fresh air deep dehumidification air-conditioning system,and analyses the characteristics of system energy saving and annual operation economy.Identifies the clean air-conditioning system of fresh air deep dehumidification combining with the energy efficient techniques,which contents the functional requirement and realizes energy saving.