中继站自动闭塞区段继电式区间逻辑检查电路及应急处置 被引量:2

Relay-based Interval Logic Checking Circuit and Emergency Treatment in Automatic Block Section of Relay Station
下载PDF
导出
摘要 继电式区间逻辑检查功能作为列车占用丢失报警判断的方法之一,为列车运行提供安全防护。通过分析中继站继电式区间逻辑检查电路,可以熟练掌握主控站对中继站的逻辑检查报警判断,为电务人员提供应急处置措施。 As one of the methods to determine the alarm of train occupancy loss,the relay-based section logic check function provides safety protection for train operation.By analyzing the relay–based section logic check circuit of relay station,this paper not only enable the staff to master logic check alarm judgment of the master station to the relay station,but also provide emergency measures.
作者 郭少雄 Guo Shaoxiong(Jiayuguan Signal&Telecomm Depot,China Railway Lanzhou Group Co.,Ltd.,Jiayuguan 735100,China)
出处 《铁路通信信号工程技术》 2020年第10期88-92,103,共6页 Railway Signalling & Communication Engineering
关键词 区间逻辑检查 占用丢失 继电式电路 应急处置 section logic check train occupancy loss relay-based circuit emergency response