摘要 为满足超导射频腔及超导磁体低温下的加速器准直精度要求,对超流氦低温恒温器冷质量的准直调节方案进行分析。通过对冷质量的低温位移进行有限元模拟计算,获得其在2 K超流氦温区的位移变形量,利用拉伸丝型位移监测仪(WPM)在线测量数据来验证模拟分析方法。结果表明,模拟值与测量值具有较好的一致性,为底部支撑型式低温恒温器的准直调节方案设计提供了重要的数据基础。 To meet the alignment requirement of superconducting radio frequency(SRF)cavity and superconducting magnet at cryogenic temperature in the accelerator system,the design of adjustment and alignment of the cold mass in superfluid helium cryomodule should be analyzed.The cryogenic deformation of the cold mass at the 2 K superfluid helium temperature level was simulated and obtained by the finite element method,meanwhile the simulation analysis method was checked by the cryogenic deformation data of the cold mass online measured by the wire of position monitor(WPM).The results show that the simulation result and measurement result have a good consistency,and it provides an important data foundation for the alignment design in the type of bottom supported cryomodule.
作者 韩瑞雄 邹正平 朱洪岩 常正则 葛锐 李少鹏 HAN Ruixiong;ZOU Zhengping;ZHU Hongyan;CHANG Zhengze;GE Rui;LI Shaopeng(School of Energy and Power Engineering,Beihang University,Beijing 100191,China;Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049,China)
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2020年第10期1979-1984,共6页 Atomic Energy Science and Technology
基金 中国科学院战略性先导科技专项资助项目(XDA030213)。
关键词 超流氦 低温恒温器 低温位移 拉伸丝型位移监测仪 准直 superfluid helium cryomodule cryogenic deformation wire of position monitor alignment
  • 相关文献

参考文献6

二级参考文献45

  • 1熊莉芳,林源,李世武.-湍流模型及其在FLUENT软件中的应用[J].工业加热,2007,36(4):13-15. 被引量:144
  • 2Gassner G. Experience Report with the Alignment Diagnostic System. SLAC Stanford. 2010. 被引量:1
  • 3YUAN Ren-Xian. Study and Application of Beam Position Measurement. Beijing. IHEP. 2004. 被引量:1
  • 4Deibele C. Synthesis and Considerations for OptimallyMatch- ing to a Beam Position Monitor Circuit Impedance, SNS- NOTE-DIAG-31. 被引量:1
  • 5Bosotti A, Pagani C, Varisco G. On Line Monitoring of the TTF Cryostats Cold Mass with Wire Position Monitors.INFN/TC- 00/02 (Mar 17, 2000). 被引量:1
  • 6Giove D, Bosotti A, Pagani C. A Wire Position Monitor (WPM) System to Control the Cold Mass Movements Inside the TRF Cryomodule. Particle Accelerator Conference. 1997. 被引量:1
  • 7Shafer R E. Beam Position Monitor Sensitivity for Low-beta Beams. AIP Conference Proceedings 319. New York: Ameri- can Institute of Physics, 1994. 303-308. 被引量:1
  • 8Peter Forck, PiotrKowina, Dmitry Liakin. Beam position mon- itor. Helmholtz Centre for Heavy Ion Research GSI. Germany. 2008. 被引量:1
  • 9Bosotti A, Pagani C and Varisco G. Online monitoring of the TTF cryostats cold mass with wire position monitors. INFN-LNF-TC-00-2, 2000. 被引量:1
  • 10Bedeschi F, Bellettini G, Bosotti A, et al. A new wire position monitor readout system for ILC cryomodules. IEEE Nucl Sci Conf R, 2007, 1684-1686. DOI: 10.1109/NSS-MIC.2007.4437324. 被引量:1