摘要
This paper describes the design and preliminary test of the low-level radio frequency(LLRF)part of the C band high-gradient test facility for the Shanghai Soft X-ray Free-Electron Laser(SXFEL)-Linear Accelerator(LINAC).Before installation,the accelerating structures should be tested and conditioned.During the conditioning process,breakdown detection is needed to protect the accelerating structures and klystron from damage.The PCI extensions for instrumentation-based LLRF system and auto-conditioning algorithm are designed and applied in the LLRF part of the C band high-gradient test facility.Three C band accelerating structures and 1 pulse compressor have completed conditioning and were installed in the SXFEL-LINAC.
基金
This work was supported by the National Key R&D Program of China(No.2018YFF0109203).