利用加速器的工程CAD模型和MCNP计算文件获得的辐射剂量分布图,定性分析了加速器周围的辐射场分布,并结合国家相关标准GB/T20129-2015对加速器防护性能的剂量学相关指标进行了模拟计算和优化分析.研究结果表明在加速器初步设计的状态下,利用CAD精确建模和MC模拟计算的方式进行加速器防护性能指标的快速检测和评价具有一定可行性,并以此为基础进行加速器屏蔽结构、材料设置的优化.
The radiation dose distribution map obtained from the engineering CAD model of the accelerator and the MCNP calculation file was used to qualitatively analyze the radiation field distribution around the accelerator,and the dosimetry related indexes of the accelerator protection performance are simulated and optimized according to national standard G B/T 20129—2015.The research results show that it is feasible to use CAD accurate modeling and MC simulation calculation to quickly detect and evaluate the protective performance index of the accelerator under the condition of the preliminary design of the accelerator,and optimize the shielding structure and material setting of the accelerator.
作者
李占鹏
王一迪
唐波
李想
汤薇
高宇楠
高韩
孙亮
LI Zhan-peng;WANG Yi-di;TANG Bo;LI Xiang;TANG Wei;GAO Yu-nan;GAO Han;SUN Liang(State Key Laboratory of Radiation Medicine and Protection,Soochow University,Suzhou Jiangsu 215123,China;School of Radiation Medicine and Protection,Medical College of Soochow University,Suzhou Jiangsu 215123,China;Collaborative Innovation Centre of Radiation Medicine of Jiangsu Higher Education Institutions,Suzhou Jiangsu 215123,China)
出处
《核电子学与探测技术》
CAS
北大核心
2020年第1期133-138,共6页
Nuclear Electronics & Detection Technology
基金
国家自然科学基金(11575124)
核能开发项目([2016]1295号)资助。
关键词
无损检测加速器
屏蔽设计与优化
MC模拟
剂量分布
industrial non-destructive testing accelerator
shielding design and optimization
Monte Carlo
dose distribution