安徽某半开放演出建筑中庭采暖的优化研究

Optimization Research on Atrium Heating in a Semi-open Performance Building in Anhui Province
下载PDF
导出
摘要 对安徽某半开放的演出建筑冬季采暖设计进行了优化。论文采用数值模拟的方法,通过改变送风口的射流角度,对该建筑在3种不同空调供暖方式9种工况下的室内气流分布和热环境进行优化选择,从喷口尺寸,送风速度,喷口高度,喷口排列方式进行优化,对优化过的方案进行热舒适性分析,通过PMV、PPD等热舒适性指标验证优化方案的合理性,最终确定喷口送风+地面辐射复合供暖为最优方案。 The winter heating design of the performance building in Anhui Province was optimized. The paper uses numerical simulation method to optimize the indoor air distribution and thermal environment of the building under three different air conditioning modes. The nozzle size, air supply speed, nozzle height and nozzle arrangement was optimized,and the thermal comfort of the optimized solution was analyzed, and the rationality of the optimization scheme was verified through thermal comfort indicators such as PMV and PPD. It is finally determined that the nozzle air supply +ground radiation composite heating is the optimal solution.
作者 史鑫 梁珍 SHI Xin;LIANG Zhen(School of Environmental Science and Engineering,Donghua University)
出处 《建筑热能通风空调》 2020年第7期63-66,77,共5页 Building Energy & Environment
关键词 中庭 CFD模拟 燃气辐射 地板辐射 踢脚线散热片 atrium CFD simulation gas radiation floor radiation baseboard heats
  • 相关文献

参考文献3

二级参考文献28

  • 1李廷贤,刘艳华.地表装饰材料和保温层性能对辐射地板热量损失影响的数值研究[J].暖通空调,2004,34(11):19-23. 被引量:12
  • 2夏学鹰.地板辐射采暖的技术经济性分析[J].南京师范大学学报(工程技术版),2004,4(4):35-36. 被引量:4
  • 3张伟,朱家玲,苗常海.低温地板采暖与散热器采暖效果的对比分析[J].太阳能学报,2005,26(3):304-307. 被引量:32
  • 4Augnstin N,Ajah A C.Patil P M.et al.Integrated conceptual design of a robust and reliable waste-heat district heating system[J].Applied Thermal Engineering,2007,27:1158-1164. 被引量:1
  • 5Torekov M S,Bahnsenb N,Qvale B.The relative competitive positions of the alternative means for domestic heating[J].Energy,2007,32:627-633. 被引量:1
  • 6Bozkir O,Canbazoglu S.Unsteady thermal performance analysis of a room with serial and parallel duct radiant floor heating system using hot airflow[J].Energy and Buildings,2004,36:579-586. 被引量:1
  • 7Lin K P,Zhang Y P,Di H F, et al.Study of an electrical heating system with ductless air supply and shape-stabilized PCM for thermal storage[J]. Energy Conversation and Management,2007,48:2016-2024. 被引量:1
  • 8S.Sattari,B.Farhanieh.A parametric study on radiant floor heating sys- tem performance[J].Renewable Energy,2006,31:1617-1626. 被引量:1
  • 9Gook-Sup Song.Buttock temperature in a sedentary posture on ply- wood flooring of varying thickness over the ONADOL heating system [J]. Wood Sei.,2004,50:498-503. 被引量:1
  • 10Balta M T,Kalinci Y,Hepbasli A.Evaluating a low exergy heating sys- tem from the power plant through the heat pump to the building envelope[J]. Energy and Buildings,2008,40:1799-1804. 被引量:1