期刊文献+

辅助125I粒子植入器械包联合腹部125I粒子植入防护铅褂在恶性梗阻性黄疸125I粒子支架植入患者中的应用及效果 被引量:3

The application of self-made auxiliary I seed implantation device package and abdominal I seed implantation protective lead apron in biliary I seed stent implantation for malignant obstructive jaundice
下载PDF
导出
摘要 目的探讨自制辅助125I粒子植入器械包联合腹部125I粒子植入防护铅褂在恶性梗阻性黄疸125I粒子支架植入患者中的应用及效果。方法选择行胆道125I粒子支架植入术的恶性梗阻性黄疸患者80例,随机分成实验组和对照组各40例。实验组患者术中医师使用自主创新的辅助125I粒子植入器械包(专利号:ZL201620728909.3),术后患者穿自主创新的腹部125I粒子植入防护铅褂(专利号:ZL201620839740.9);对照组患者术中医师采用传统粒子植入手术器械,术后患者穿常规防护铅衣。比较两组患者术中医师精确植入1颗粒子所用的时间,术后两种铅衣的辐射屏蔽效果、患者主动防护的持续时间及患者舒适度。采用SPSS23.0软件包对数据进行统计学分析。结果两组患者术中医师精确植入1颗粒子所用的时间差异有显著统计学意义(t=-6.974,P<0.001),两组患者穿戴不同铅衣进行放射性防护后间隔0 m距离、0.5 m距离时的辐射携带量差异均无统计学意义(t0m=1.449,t0.5m=0.08633,P均>0.05)、两组患者主动穿防护铅衣的持续时间差异有统计学意义(t=7.866,P<0.05),两组患者舒适度差异有统计学意义(Z值=-2.193,P<0.05)。结论辅助125I粒子植入器械包联合腹部125I粒子植入防护铅褂应用于恶性梗阻性黄疸125I粒子支架植入患者中,可提高医师手术工作效率,减少受粒子辐射的照射时间,可提高患者主动防护辐射的依从性及舒适度,具有临床应用价值及推广意义。 Objective To discuss the application of self-made auxiliary125I seed implantation device package and abdominal125I seed implantation protective lead apron in biliary125I seed stent implantation for malignant obstructive jaundice(MOJ),and to evaluate its clinical effect.Methods A total of 80 patients with MOJ,who were scheduled for biliary125I seed stent implantation,were enrolled in this study.The patients were randomly and equally divided into study group and control group with 40 patients in each group.In performing biliary125I seed stent implantation for patients of the study group,the operators used independently-innovated auxiliary125I seed implantation device package(patent No.ZL201620728909.3),and after the procedure the patients were asked to wear the independently-innovated abdominal125I seed stent implantation protective lead apron(patent No.ZL201620839740.9);while in performing biliary125I seed stent implantation for patients of the control group,the operators used traditional surgical instruments for125I seed implantation,and after the procedure the patients were asked to wear conventional protective lead apron.The time spent for accurately implanting one125I seed,the radiation shielding effect of the two kinds of protective lead apron,the duration of patients’active protection,and the patient’s comfortableness degree were compared between the groups.Statistical analysis of the data was carried out by using SPSS 23.0 software package.Results Statistically significant difference in the time spent for accurately implanting one125I seed existed between the two groups(t=-6.974,P<0.001),while no statistically significant difference in the radiation dose(at 0 m and 0.5 m pacing distance)after wearing different protective lead aprons existed between the two groups(t0m=1.449,t0.5m=0.0833,P>0.05 in both).There were statistically significant differences in the duration of patients’active protection(t=7.866,P<0.05)and in the patient’s comfortableness degree(Z=-2.193,P<0.05)between the two groups.Conclusi
作者 邱岚茜 邱燕 蒋蕾 杨卓林 王琼波 张艳萍 张丽琴 李俊锋 蒋妮 QIU Lanxi;QIU Yan;JIANG Lei;YANG Zhuolin;WANG Qiongbo;ZHANG Yanping;ZHANG Liqin;LI Junfeng;JIANG Ni(Department of Minimally-Invasive Interventional Therapy,Third Affiliated Hospital of Kunming Medical University,Yunnan Provincial Tumor Hospital,Kunming,Yunnan Province 650118,China)
出处 《介入放射学杂志》 CSCD 北大核心 2020年第8期829-833,共5页 Journal of Interventional Radiology
基金 云南省教育厅科学研究基金(2019J1266)。
关键词 粒子植入器械包 粒子防护铅褂 梗阻性黄疸 125I放射性粒子 seed implantation package 125I seed protection lead apron obstructive jaundice radioactive125I seed
  • 相关文献

参考文献8

二级参考文献77

共引文献120

同被引文献39

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部