摘要
回顾了自动喷水灭火系统的发展历程,介绍了响应时间指数、实际洒水密度、必需洒水密度、灭火临界条件等自动喷水核心技术,概述了大水滴喷头、早期抑制快速响应喷头、特殊应用控火型喷头等喷头技术的应用.
The development of sprinkler system is reviewed,the core technologies of sprinkler system such as response time index,actual delivered density,required delivered density,critical conditions for fire suppression are introduced.The application of large drop sprinkler,early suppression fast response sprinkler,control mode specific application sprinkler are summarized.
作者
黄晓家
赵耀
谢水波
吴懂礼
杨世全
尧炜杰
Huang Xiaojia;Zhao Yao;Xie Shuibo;Wu Dongli;Yang Shiquan;Yao Weijie(China IPPR International Engineering Co.,Ltd.,Beijing 100089,China;School of Civil Engineering,University of South China,Hengyang 421001,China)
出处
《给水排水》
CSCD
北大核心
2020年第8期84-89,共6页
Water & Wastewater Engineering
基金
国家重点研发计划课题(2018YFC0807605)。
关键词
自动喷水灭火系统
响应时间指数
实际洒水密度
必需洒水密度
早期抑制快速响应喷头
特殊应用控火型喷头
Sprinkler system
Response time index
Actual delivered density
Required delivered density
Early suppression fast response sprinkler
Control mode specific application sprinkler