曲面太阳能集热器与平板太阳能集热器的性能对比实验研究

EXPERIMENTAL STUDY ON PERFORMANCE COMPARISON BETWEEN CURVED SOLAR COLLECTOR AND FLAT SOLAR COLLECTOR
下载PDF
导出
摘要 目前传统的平板太阳能集热器存在占地面积大、集热性能差等缺点,在一定程度上制约了其在中国的推广及应用,而新型的曲面太阳能集热器的集热性能有大幅提升。通过实验平台测试了曲面太阳能集热器与平板太阳能集热器在2种安装角度时的集热性能,并分析了这2种太阳能集热器的集热性能差异。结果显示,在相同安装角度时,曲面太阳能集热器的集热效率高于平板太阳能集热器的。 At present,the traditional flat solar collector have the disadvantages of large area and poor heat collection performance,which restrict its promotion and application in China.The performance of novel curved solar collector has been greatly improved.This paper introduces the heat collection performance tests of curved solar collector and flat solar collector under two installation conditions on one experimental platform.The analysis of the difference between the heat collection performance of two kinds of solar collectors is proposed.The results show that under the same installation angle,the heat collection efficiencies of the curved solar collector are higher than that of flat solar collector.
作者 鄢雨 沈国民 张豪 王飞飞 吴祖国 Yan Yu;Shen Guomin;Zhang Hao;Wang Feifei;Wu Zuguo(Department of Building Envioronment and Energy Engineering,Huazhong University of Science and Technology,Wuhan 430000,China;Wuhan Boming Low Carbon Industry Co.,Ltd.,Wuhan 430000,China)
出处 《太阳能》 2020年第8期70-75,共6页 Solar Energy
关键词 太阳能集热器 曲面太阳能集热器 平板太阳能集热器 集热性能 集热效率 solar collector curved solar collector flat solar collector heat collection performance heat collection efficiency
  • 相关文献

参考文献4

二级参考文献43

  • 1清华大学建筑节能研究中心.中国建筑节能年度发展研究报告:2013[M].北京:中国建筑工业出版社,2013. 被引量:2
  • 2UN.World Urbanization Prospects,the 2014 revisions [M].Department of Economic and Social Affaris,United Nations,2014. 被引量:1
  • 3IEA.Cities,Towns and Renewable Energy,International Energy Agency (IEA)[M].2009. 被引量:1
  • 4STEEMERS K.Energy and the city:density,buildings and transport[J]. Energy and Buildings,2003,35( 1):3-14. 被引量:1
  • 5CHOUDHARY R,TIAN W.Influence of district features on energy con- sumption in non-domestic buildings[J] .Building Research and Information, 2014,42( 1 ):32-46. 被引量:1
  • 6TIAN W,CHOUDHARY R.Energy use of buildings at urban scale:a case study of London schoo buildings[M].IBPSA 2011,November 14-16, Sydney,2011. 被引量:1
  • 7TIAN W,SONG J,LI Z.Spatial regression analysis of domestic energy in urban areas[J].Energy,2014,76:629-640. 被引量:1
  • 8JTIAN W, CHOUDHARY R.Spatial analysis of gas consumption by non-domestic buildings in Greater London[C]//The 5th International Build- ing Physics Conference,Kyoto,Japan,28-31 May,2012. 被引量:1
  • 9TIAN W, WANG Y,XIE Y,et al.Effect of building integrated photo- voltaics on microclimate of urban canopy layer[J].Building and environment, 2007,42(5):1891-1901. 被引量:1
  • 10YAMAGUCHI Y,YOSH1YUKI S.Database and simulation model de- velopment for modelling the energy use of non-residential buildings[C]//Pro- ceedings of the 1 lth International IBPSA Conference, Glasgow, Scotland, 2009. 被引量:1