期刊文献+

基于HPPP法标准装置就压力对涡轮流量计影响研究 被引量:2

The Pressure Effect on the Turbine Flowmeter Based on HPPP Standard Facility
原文传递
导出
摘要 基于测量不确定度0.07%(k=2)的两套HPPP法标准装置,在2~8MPa压力范围内,就压力对涡轮流量计计量性能的影响开展实验研究,测试结果表明,相同流量下,不同压力,涡轮流量计的误差变化可超过0.18%。基于该测试结果,提出适用于高雷诺数的涡轮流量计误差曲线拟合公式,并对公式的适用性予以了验证。 Based on two sets of HPPP standard facilities with the uncertainty of 0.07%(k=2),an experimental study on the influence of pressure on the metering performance of the turbine flowmeter was carried out in the pressure range of 2~8 MPa.The test results showed that the change of error for the turbine flowmeter could exceed 0.18% at the different pressure with the same flowrate.Based on the test results,the curve fitting formula suitable for the turbine flowmeters with high Reynolds number was proposed and verified.
作者 裴勇涛 李春辉 徐明 PEI Yongtao;LI Chunhui;XU Ming(The Center of Metrology Research,Sinopec Tianranqi company,Wuhan 430073,China;National Institute of Metrology,Beijing 100029,China)
出处 《计量技术》 2020年第4期57-60,共4页 Measurement Technique
基金 国家重点研发计划(2017YFF0205305),。
关键词 HPPP法标准装置 涡轮流量计 压力 误差 拟合曲线 HPPP standard facility turbine flowmeter pressure error curve fitting
  • 相关文献