结合某工程旋挖嵌岩灌注桩检测实例,针对其桩底沉渣引发质量异常情况,采取3种基桩检测方法进行综合判定,分析其质量异常原由,提出加固处理措施。
Combined with the test example of rotary rock-socked cast-in-situ pile in a project,according to at the abnormal quality caused by the sediment at pile tip,three kinds of foundation pile testing methods are adopted for comprehensive judgment,analyze the cause of the quality anomaly,and put forward reinforcement measures.
作者
邵远扬
SHAO Yuanyang(Fujian Institute of Building Science Co.Ltd,Fujian Provincial Key Laboratory of Green Building Technology,Fuzhou 350108)
出处
《福建建筑》
2020年第6期54-57,共4页
Fujian Architecture & Construction
关键词
旋挖灌注桩
嵌岩
沉渣
检测
处理
Rotary cast-in-situ pile
Rock-socked
Sediment
Testing
Treatmen