期刊文献+

火焰原子吸收分光光度法(FAAS)和电感耦合等离子体发射光谱法(ICP-AES)对比研究 被引量:10

Comparative Study between Flame Atomic Absorption Spectrophotometry and Inductively Coupled Plasma Emission Spectrometry
下载PDF
导出
摘要 采用火焰原子吸收分光光度法(FAAS)和电感耦合等离子体发射光谱法(ICP-AES)测定文山盘龙河水中铁和锰,研究对比了两种测定方法对铁和锰两种元素测定的准确性、加标回收率及精密度。实验结果表明:两种方法测定盘龙河水中铁和锰的结果均具有良好的准确度和精密度。 FAAS and ICP-AES were used to determine the ferrum and manganese in the water of Panlong River in Wenshan.The accuracy of the two methods for the determination of the two metals was studied.The results showed that the two methods had good accuracy and precision in the determination of ferrum and manganese of the water of Panlong River.
作者 倪伟茗 NI Wei-ming(Wenshan Environmental Monitoring Station,Wenshan Yunnan 663099,China)
出处 《环境科学导刊》 2020年第S01期106-110,共5页 Environmental Science Survey
  • 相关文献

参考文献2

二级参考文献9

共引文献6

同被引文献65

引证文献10

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部