期刊文献+

基于集总参数模型的人工耳蜗圆窗植入位置对残余听力影响分析 被引量:2

Investigating the Effect of Cochlear Implant Round Window Insertion Position on Residual Hearing using A Lumped Parameter Model
下载PDF
导出
摘要 人工耳蜗植入是目前治疗重度到极重度感音性耳聋的有效方法。低频残余听力能够让患者具有较好的言语识别及音乐鉴赏能力,因此在人工耳蜗植入术中保护患者残余听力具有重要意义。本文主要探讨人工耳蜗通过圆窗植入时的不同位置对残余听力可能带来的影响。研究首先基于医学影像利用有限元方法对耳蜗圆窗膜进行建模,将其简化为椭圆形平板结构;随后计算分析了10种人工耳蜗电极在圆窗上的植入位置对圆窗膜刚度变化的影响;进而通过集总参数模型预测了不同圆窗植入位置对残余听力的影响。研究发现,相对圆窗中心沿长轴方向偏移较远的植入方案可以帮助有效保护残余听力。 The cochlear implant(CI)is an effective rehabilitation method for severe and profound sensorineural hearing loss.It is important to preserve low-frequency residual hearing during the CI surgery,since this would provide patients with better speech recognition and music appreciation abilities.The aim of this paper is to investigate effects of different insertion positions via the round window(RW)on residual hearing.The finite element method was used to model the round window based on medical images,in which the RW membrane was simplified as an elliptical plane structure.Ten assumptive insertion positions were used for analyzing RW membrane stiffness changes at different frequencies after implantation.A lumped parameter model was then used to predict residual hearing with different insertion positions.The conclusion is that the farther the inserting position away from the RW center along its long axis,the better residual hearing will be preserved.
作者 倪广健 庞嘉 高搏 蒋刈 戴朴 明东 NI Guangjian;PANG Jia;GAO Bo;JIANG Yi;DAI Pu;MING Dong(Department of Biomedical Engineering,College of Precision Instruments and Optoelectronics Engineering,Tianjin University,Tianjin,P.R.China;Academy of Medical Engineering and Translational Medicine,Tianjin University,Tianjin,P.R.China;Department of Otolaryngology,Head and Neck Surgery,PLA General Hospital,Beijing,P.R.China;Department of Otolaryngology,Fujian Medical University Provincial College of Clinical Medicine,Fujian Provincial Hospital,Fuzhou,P.R.China)
出处 《中华耳科学杂志》 CSCD 北大核心 2020年第3期564-569,共6页 Chinese Journal of Otology
基金 京津冀基础研究合作专项(18JCZDJC45300) 国家自然科学基金(81971698) 天津市留学人员科技活动启动项目择优资助计划(2018004)。
关键词 人工耳蜗 圆窗植入 残余听力 有限元分析 集总参数模型 Cochlear implant Round window implantation Residual hearing Finite element analysis Lumped parameter model
  • 相关文献

参考文献7

二级参考文献101

  • 1冀飞,郗昕,洪梦迪,韩东一,黄德亮,武文明.语前聋人工耳蜗植入患者听觉和言语康复效果的问卷分级评估[J].中华耳鼻咽喉科杂志,2004,39(10):584-588. 被引量:63
  • 2陈雪清,王靓,孔颖,刘莎,刘博,莫玲燕,王硕,吴燕君,韩娜,孟黎晖,李海珍.用有意义听觉整合量表评估儿童人工耳蜗植入后听觉能力[J].中华耳鼻咽喉头颈外科杂志,2006,41(2):112-115. 被引量:39
  • 3Goycoolea MV. Clinical aspects of round window membrane permeability undernormal and pathological conditions[J]. Acta Otolaryngol,2001,121(4):437-447. 被引量:1
  • 4Kitamura Y, Teranishi M, Sone M, et al. Round window membrane in young and aged C57BL/6 mice[J]. Hear Res,2002,174(1-2):142-148. 被引量:1
  • 5Alec N. Quantification of solute entry into cochlear perilymph through the round window membrane[J]. Hearing Res,2001,154(1-2): 88-97. 被引量:1
  • 6Takahashi H, Honjo I,Sando I,et al. Orientation for cochlear implant surgery in cases with round window obstruction: a computer reconstruction study[J]. Eur Arch Otorhinolaryngol,1995,252(2):102-105. 被引量:1
  • 7Carpenter AM, Muchow D, Goycoolea MV, et al. Ultrastructural studies of thehuman round window membrane[J]. Arch Otolaryngol Head Neck Surg, 1989,115(5):585-590. 被引量:1
  • 8Takahashi H, Sando I, Takagi A. Computer aided three-dimensional reconstruction and measurement of the round window niche[J]. Laryngoscope,1989,99(5):505-509. 被引量:1
  • 9Takahashi H, Takagi A, Sando I. Computer-aided three dimensional reconstruction and measurement of the round window and its membrane[J]. Otolaryngol Head Neck Surg,1989,101(5):517-521. 被引量:1
  • 10Adam F. Quantitative anatomy of the round window and cochlear aqueduct in guinea pigs[J]. Hearing Res,2001,162(1-2): 105-112. 被引量:1

共引文献39

同被引文献5

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部