摘要 为了定量分析光电探测器响应特性,需要对光电探测器进行标定。针对传统的光电探测器标定方法上的不足,提出了一种新的标定方法,该方法具有标定精度高,适用于各个波段的光电探测器等特点。试验结果表明,经过标定后的硅材料光电探测器测量精度可达3.45%,对光电探测器的标定检测具有参考价值。 In order to quantitatively analyze the response characteristics of the photodetector,the photodetector needs to be calibrated.Aiming at the shortcomings of the traditional photodetector calibration method,a new calibration method was proposed.The method has the characteristics of high calibration accuracy and is suitable for photodetectors in various bands.The test results show that the accuracy of the calibrated silicon material optoelectronics detector can reach 3.45%.This method has certain guiding significance for the calibration work of the photodetector.
作者 蔡修青 谭逢富 秦来安 靖旭 侯再红 吴毅 CAI Xiu⁃qing;TAN Feng⁃fu;QIN Lai⁃an;JING Xu;HOU Zai⁃hong;WU Yi(School of Environmental Science and Optoelectronic Technology,University of Science and Technology of China,Hefei 230026,China;Key Laboratory of Atmospheric Optics,Anhui Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,Hefei 230031,China)
出处 《仪表技术与传感器》 CSCD 北大核心 2020年第5期28-32,共5页 Instrument Technique and Sensor
关键词 光电探测器 标定 能量密度 响应值 photodetector calibration energy density response value