期刊文献+

核电站小径薄壁管插接焊缝的相控阵超声检测

Phased array ultrasonic detection for inserted weld of small diameter thin-walled tube in nuclear power station
下载PDF
导出
摘要 小径薄壁管是核电站运行中最容易生成缺陷和发生泄漏的部件和位置。小径薄壁管插接焊缝一般采用射线法进行检测,但是射线检测存在辐射风险,检测区域需要隔离且检测工期较长,并不适于核电站大修期间的大范围应用。通过自然缺陷试块进行小径薄壁管插接焊缝相控阵超声波检测工艺分析及检测能力验证研究。在此基础上,成功将相控阵超声检测技术应用于核电大修现场并发现缺陷。 Trail thin-walled pipes are the most vulnerable parts and locations to defects and leaks in the operation of nuclear power plants.The thin walled pipe seam of the trail was generally inspected by ray method,but the ray detection had some obvious limitations.There is a radiation risk in the detection,the detection area needs to be isolated,and the length of the test period makes it impossible for radiation detection to be used on a large scale during the overhaul of the nuclear power plant.In this paper,based on the natural defect test block,the ultrasonic inspection technology and the test ability of the thin walled tube socket weld phase control array are studied.On the basis of this,practical application of the technology was successfully carried out in the field of nuclear power overhaul and some defects were actually found.
作者 贺志清 杨群 施亦斌 HE Zhiqing;YANG Qun;SHI Yibin(State Nuclear Power Plant Service Company,Shanghai 200233,China)
出处 《无损检测》 2020年第4期65-68,共4页 Nondestructive Testing
基金 国家科技重大专项(2015ZX06002005)。
关键词 核电 插接焊缝 相控阵超声 nuclear power plug weld phased array ultrasonic