摘要
根据雷神山医院低压配系统设计实例,探讨了呼吸类临时传染病医院隔离区的医技区供配电系统设计、用电负荷估算、2类医疗场所IT系统配电、不间断电源配置及重要用电设备处电能质量治理等相关问题。
According to the design example of low-voltage distribution system in leishenshan hospital,this paper discusses the design of power supply and distribution system,power load estimation,the power distribution of the IT system in the 2 medical sites,the uninterruptible power supply configuration and power quality control of important electrical equipment in the isolation area of respiratory temporary infectious diseases hospital.
作者
王彦
郑梦笛
王云鹏
曾诚
李亮
张龙
Wang Yan;Zheng Mengdi;Wang Yunpeng;Zeng Cheng;Li Liang;Zhang Long(Central South Architectural Design Institute Co.,Ltd,Wuhan 430071,China)
出处
《智能建筑电气技术》
2020年第1期109-111,共3页
Electrical Technology of Intelligent Buildings
关键词
呼吸类临时传染病医院
低压配电系统设计
用电负荷指标
respiratory temporary infectious disease hospital
design of low voltage distribution system
power load index