期刊文献+

基于超超临界锅炉水冷壁爆管的若干特征分析 被引量:2

Characteristics Analysis of Ultra-Supercritical Boiler Water-Wall Tube Burst
下载PDF
导出
摘要 通过对某电厂2号炉水冷壁鳍片开裂、包墙管鳍片开裂,拉裂管子导致的泄漏事件进行了分析,认为裂纹的原因可能是管子母材在制造、加工时存在缺陷,管道运行中自身的局部应力集中导致开裂。分析了裂纹产生的机理,提出了相应的措施以提高水冷壁管的可靠性。 This paper analyzes the leakage accidents caused by the cracking of the water-wall fin, the cracking of the cladding tube fin and the cracking of the pulled pipe of Boiler 2 in a power plant, and concludes that the cracks may be caused by the defects in the manufacturing and processing of the base material of the pipe, and the local stress concentration in the pipeline operation. The mechanism of crack generation is analyzed and the corresponding measures are put forward to improve the reliability of water-wall tube.
作者 白玉峰 林耀健 江永 冯庭有 姚友工 杨略 胡木林 BAI Yufeng;LIN Yaojian;JIANG Yong;FENG Tingyou;YAO Yougong;YANG Lue;HU Mulin(Huaneng Haimen Power Plant,Shantou 515071,Guangdong Province,China)
机构地区 华能海门电厂
出处 《电力与能源》 2020年第2期254-257,共4页 Power & Energy
关键词 超超临界 燃煤汽轮机组 电站锅炉 水冷壁爆管 ultra-supercritical coal-fired steam turbine unit power station boiler water-wall tube burst