期刊文献+

基于电感电流反馈的双向DC-DC变换器下垂控制 被引量:9

Droop Control of Bi-directional DC-DC Converters Based on Inductive Current Feedback
下载PDF
导出
摘要 该文以直流微网中广泛应用的双向DC-DC变换器为研究对象,提出基于电感电流反馈的下垂控制策略。首先,分析传统基于并网电流反馈的双向DC-DC变换器控制算法的工作原理;然后,分析传统电压外环-并网电流内环的双闭环和电压外环-电感电流内环的双闭环DC-DC变换器控制系统的稳定性,在此基础上,提出一种基于电感电流反馈的双向DC-DC变换器下垂控制方法,并对其稳定性进行分析;与传统下垂控制策略相比,所提算法在保证变流器本体稳定性的同时,能有效实现输出功率自动均衡,达到下垂控制的目的;最后,通过实验测试验证了所提算法的有效性和正确性。 In this paper, the inductor current feedback based droop control was proposed for bi-directional DC-DC converter widely used in DC microgrid. The operation principle of the traditional droop control with the output current feedback for bi-directional DC-DC converter was analyzed. And then the stability of the double closed-loop control for the bi-directional DC-DC converters with the outer loop voltage control and the inner inductance current control was analyzed in detail. Furthermore, the proposed droop control method based on inductance current feedback was proposed and the stability of the proposed method was elaborated. The proposed can effectively improve the control system stability of the DC-DC converter with the power sharing ability. The experimental tested verify correctness and effectiveness of the control system.
作者 杨翔宇 肖先勇 马俊鹏 李媛 YANG Xiangyu;XIAO Xianyong;MA Junpeng;LI Yuan(College of Electrical Engineering,Sichuan University,Chengdu 610065,Sichuan Province,China)
出处 《中国电机工程学报》 EI CSCD 北大核心 2020年第8期2638-2646,共9页 Proceedings of the CSEE
基金 国家自然科学基金项目(51707126)。
关键词 直流微网 DC-DC变流器 下垂控制 电感电流反馈 稳定性 DC microgrid DC-DC converter droop control inductance current feedback stability
  • 相关文献

参考文献12

二级参考文献178

  • 1赵涛,王相綦,尚雷,王琳,张海燕.高性能开关型直流稳压电源的设计[J].核技术,2004,27(9):645-649. 被引量:3
  • 2WANG Long XIAO Feng.A new approach to consensus problems in discrete-time multiagent systems with time-delays[J].Science in China(Series F),2007,50(4):625-635. 被引量:22
  • 3BELLOMO P, DE LIRA A. SPEAR 3 large dc magnet power supplies [ C ]// Proceedings of EPAC 2004. Lu- cerne: [s. n. ] ,2004:801 - 803. 被引量:1
  • 4SUH J H,HA K M,JEONG S H, et al. Performance of the PLS high precision magnet power supplies [ C ]// Proceedings of LINAC 2002. Gyeongju:Pohang Accel- erator Laboratory,2002:505 - 507. 被引量:1
  • 5VLATOKOVI'C V, SABAT J A, RIDLEY R B, et al. Small signal analysis of the phase shifted PWM con- verter [ J]. IEEE Transactions on Power Elect ronics, 1992,7 ( 1 ) : 128 - 134. 被引量:1
  • 6VATCHE V. Simplified analysis of PWM converters u- sing model of PWM switch part I:continuous conduc- tion mode [ J ]. IEEE Transactions on Aerospace and E- lectronic Systems, 1990,26 ( 3 ) :490 - 496. 被引量:1
  • 7MARIANK K. Transfer function of current modulator in PWM converters with current - mode control [ J ]. IEEE Transactions on Circuits and Systems, 2000,47 ( 9 ) : 1407 - 1412. 被引量:1
  • 8PHILIP C. Modeling average current mode control[ J ]. IEEE ,2000 (2) :256 - 262. 被引量:1
  • 9汤广福.基于电压源换流器的高压直流输电技术[M].北京:中国电力出版社,2009. 被引量:41
  • 10HAMMERSTROM D J. AC versus DC distribution systems did we get it right[C]//Proceedings of IEEE Power Engineering Society General Meeting, -June 24-28, 2007, Tampa, FL, USA= 1 5. 被引量:1