三相三电平四桥臂Z源逆变器漏电流抑制 被引量:6

LEAKAGE CURRENT REDUCTION OF THREE-PHASE Z-SOURCE THREE-LEVEL FOUR-LEG INVERTER FOR TRANSFORMERLESS PV SYSTEM
下载PDF
导出
摘要 提出三电平四桥臂Z源逆变器的一种新调制方法。首先,分析三相三电平四桥臂Z源逆变器的工作原理及影响其共模电压幅值及系统漏电流的影响因素,进而提出一种基于双载波的新型载波调制策略。该调制策略可实现共模电压恒定,从而有效抑制漏电流。然后搭建TI TMS320F28335 DSP+Xilinx XC3400 FPGA数字控制硬件实验平台,对所提出的新型载波调制方案进行实验研究,实验结果可验证所提出方案的有效性。 A new modulation strategy of Z-source three-level four-leg inverter is proposed in this paper. Firstly,the operation principle is analyzed,and the influence factors,related to the common mode voltage and leakage current of Z source three-phase three-level four leg inverter,are discussed. Secondly,a new modulation strategy based on the doublecarrier modulation is proposed. The proposed new method can achieve the constant common mode voltage,so the leakage current can be well attenuated. Finally,the proposed solution is carried out on the TI(Texas Instruments)TMS320 F28335 DSP + Xilinx XC3400 FPGA digital control hardware platform. The experimental results verify the effectiveness of the proposed solution.
作者 郭小强 杨勇 王宝诚 Guo Xiaoqiang;Yang Yong;Wang Baocheng(Key Laboratory of Power Electronics for Energy Conservation and Drive Control of Hebei Province,Yanshan University,Qinhuangdao 066004,China)
出处 《太阳能学报》 EI CAS CSCD 北大核心 2020年第2期325-332,共8页 Acta Energiae Solaris Sinica
基金 国家自然科学基金(51777181)。
关键词 光伏 逆变器 调制 漏电流 photovoltaic inverter modulation leakage current
  • 相关文献

参考文献1

二级参考文献30

  • 1Steigerwald R L, et al. Investigation of a family of power conditioners integrated into a utility grid[R]. United States: Sandia National Labs., Albuquerque, NM(USA),1981. 被引量:1
  • 2Baeberlin H. Evolution of inverters for grid connected PV-systems from 1989 to 2000[C]//Proceedings of 17th European Photovoltaic Solar Energy Conference. Munich, Germany, 2001: 426-430. 被引量:1
  • 3Xiao H P, Xie S J. Leakage current analytical model and application in single-phase transformerless photovottaic grid-connected inverter[J]. IEEE Transactions on Electromagnetic Compatibility, 2010, 52(4): 902-913. 被引量:1
  • 4Yang B, Li W H, Gu Y J, et al. Improved transformerless inverter with common-mode leakage current elimination for a photovoltaic grid-connected power system[J]. IEEE Transactions on Power Electronics, 2012, 27(2): 752-762. 被引量:1
  • 5Shen J M, Jou H L, Wu J C. Novel transformerless grid-connected power converter with negative grounding for photovoltaic generation system[J]. IEEE Transactions on Power Electronics, 2012, 27(4): 1818-1829. 被引量:1
  • 6Gu Y J, Li W H, Zhao Y, et al. Transformerless inverter with virtual DC bus concept for cost-effective grid-connected PV power systems[J]. IEEE Transactions on PowerElectronics, 2013, 28(2): 793-805. 被引量:1
  • 7Wang H, Blaabjerg F. Reliability of capacitors for DC-link applications in power electronic converters : an overview[J]. IEEE Transactions on Industry Applications, 2014, 50(5): 3569-3578. 被引量:1
  • 8Wang H, Liserre M, Blaabjerg F. Toward reliable power electronics: Challenges, design tools, and opportunities [J]. IEEE Industrial Electronics Magazine, 2013, 7(2): 17-26. 被引量:1
  • 9Song Y T, Wang B S. Survey on reliability of power electronic systems[J]. IEEE Transactions on Power Electronics, 2013, 28(1): 591-604. 被引量:1
  • 10Wu B, Pontt J, Rodrignez J, et al. Current-source converter and cycloconverter topologies for industrial medium-voltage drives[J] . IEEE Transactions on Industrial Electronics, 2008, 55(7): 2786-2797. 被引量:1