摘要
针对直流炉发电机组易发生流动加速腐蚀(FAC),造成水汽系统中设备的结垢、积盐速率偏高等问题,结合案例分析介绍了FAC机理、铁腐蚀产物迁移过程及FAC抑制方法等。结果表明通过给水加氧处理(OT)可有效抑制直流炉发电机组FAC发生。
To solve the problem that flow accelerated corrosion(FAC)is easy to occur in once-through boiler units,which may result in a higher rate of scaling and salt accumulation in the equipment of related water-steam systems,an introduction was presented on the FAC mechanism,the migration process of iron corrosion products and the FAC inhibition methods,based on case analysis.Results show that the FAC in once-through boiler units could be effectively inhibited by feed water oxygenation treatment(OT).
作者
于洋
康艳昌
周洋
Yu Yang;Kang Yanchang;Zhou Yang(Huadian Electric Power Research Institute Co., Ltd., Jinan 250014, China)
出处
《发电设备》
2020年第2期87-91,共5页
Power Equipment
关键词
直流炉
FAC
铁腐蚀产物
once-through boiler
FAC
iron corrosion product