期刊文献+

直流炉发电机组中流动加速腐蚀机理及抑制方法 被引量:5

Mechanism of FAC in Once-through Boiler Units and the Corresponding Inhibition Methods
下载PDF
导出
摘要 针对直流炉发电机组易发生流动加速腐蚀(FAC),造成水汽系统中设备的结垢、积盐速率偏高等问题,结合案例分析介绍了FAC机理、铁腐蚀产物迁移过程及FAC抑制方法等。结果表明通过给水加氧处理(OT)可有效抑制直流炉发电机组FAC发生。 To solve the problem that flow accelerated corrosion(FAC)is easy to occur in once-through boiler units,which may result in a higher rate of scaling and salt accumulation in the equipment of related water-steam systems,an introduction was presented on the FAC mechanism,the migration process of iron corrosion products and the FAC inhibition methods,based on case analysis.Results show that the FAC in once-through boiler units could be effectively inhibited by feed water oxygenation treatment(OT).
作者 于洋 康艳昌 周洋 Yu Yang;Kang Yanchang;Zhou Yang(Huadian Electric Power Research Institute Co., Ltd., Jinan 250014, China)
出处 《发电设备》 2020年第2期87-91,共5页 Power Equipment
关键词 直流炉 FAC 铁腐蚀产物 once-through boiler FAC iron corrosion product
  • 相关文献

参考文献4

二级参考文献22

  • 1丁训慎.核电厂蒸汽发生器运行中的安全问题[J].核安全,2004,3(4):29-34. 被引量:5
  • 2谢剑山.600MW超临界机组给水联合处理应用分析[J].能源工程,2005,25(4):33-37. 被引量:4
  • 3DL/T805.1-2002火电厂汽水化学导则第1部分:直流锅炉给水加氧处理[S]. 被引量:2
  • 4DL/T912-2005,超临界火力发电机组水汽质量标准[S]. 被引量:15
  • 5刘崇刚.超超临界锅炉水冷壁结垢原因分析圾预防措施[c]//600/1000MW超超临界机组技术交流2009年会论文集.上海.2009:159-165. 被引量:1
  • 6DL/T5068-2006,火力发电厂化学设计技术规程[S]. 被引量:26
  • 7龚询洁.热力设备的腐蚀与防护[M].北京:中国电力出版社,1999. 被引量:1
  • 8Dooley R B, Shields K J, Shulder S J, et al. EPRI's Guideline on Chemistry for Fossil Units with Air- cooled Condensers (ACCs) [R]. EPRI, 2009. 被引量:1
  • 9Dooley R B, Shields K J, Shulder S J, et al. EPRI's Guideline on Chemistry for Fossil Units with Air- cooled Condensers (ACCs) [R]. EPRI, 2009. 被引量:1
  • 10Bindi Chexal, Jeffrey Horowitz, Barry Dooley, et al. Flow-accelerated corrosion in power plant[R]. EPRI, 1998. 被引量:1