摘要
为了研究模拟手的应用及试验布置对电磁兼容试验的影响,本文在对电磁兼容产品类标准YY 0505-2012、通用标准GB 4824-2013以及基础标准GB/T 6113.102-2008学习研究的基础上,通过对电生理诊断类设备进行传导发射、传导骚扰抗扰度及电快速瞬变脉冲群的相关试验验证,发现模拟手的应用及试验布置对其确实有不可忽略的影响。从原理上分析模拟手产生影响的原因,正确理解模拟手的原理,有助于EMC试验的检测规范。
In order to research the influences of application of artificial hand and test set-up to EMC tests,studies were performed on the EMC product Class Standard YY 0505-2012,the General Standard GB 4824-2013 and the basic standard GB/T 6113.102-2008.Relevant test verification was conducted on the electrophysiological diagnostic equipment,which including conducted emissions,conducted RF disturbance and electrical fast transient/burst immunity,we found that the application of the artificial hand and the test set-up could not be ignored.It is helpful for testing specification of EMC test to understand the principle of artificial hand correctly by analyzing the reason of influence of artificial hand.
作者
刘美丽
张淑溢
王晓慧
李庆雨
施燕平
LIU Meili;ZHANG Shuyi;WANG Xiaohui;LI Qingyu;SHI Yanping(Department of Electromagnetic Compatibility Room,Shandong Quality Inspection Center for Medical Devices,Jinan Shandong 250101,China)
出处
《中国医疗设备》
2020年第3期14-16,41,共4页
China Medical Devices
基金
国家重点研发计划(2016YFC0106001)。
关键词
模拟手
电磁兼容
传导发射
传导抗扰
脉冲群
artificial hand
electromagnetic compatibility
conducted emission
conducted immunity
pulses